3745 and Service Processor Maintenance
Engineering Data Transfer
Overview
The engineering data can be transferred in two main ways:
Optical disk or diskettes
DCAF (Distributed Console Access Facility) via LAN, or SDLC.
The transfer can be done from:
The local service processor using optical disk or diskettes
The remote service processor using DCAF.
Transferring Engineering Data from the Local Service Processor
You should be logged ON.
On the MOSS-E View window, double-click on the service processor icon.
On the Service Processor Menu, click on the Operation Management option.
Double-click on the Retrieve Engineering Data option.
The Retrieve Engineering Data window is displayed, askin g if you have transferred the 3745 engi-
neering data.
– If you click on YES:
The Engineering Data Retrieval window is displayed with a wait message. The
Save/Transfer Engineering Data window becomes available for selection.
- Click on your Copy to Diskette or Copy to Optical Disk option. Then follow the information
displayed.
- At the end of the copy, double click on the Delete Engineering data window to delete the
engineering data file on MOSS-E.
– If you click on NO you are directed to the MIP: Start page - 3745/3746-900 Maintenance
Actions. See “Transferring 3745 Engineering Data to MOSS-E.”
Transferring 3745 Engineering Data to MOSS-E
From the MOSS-E View window, double-click on the 3745 icon.
On the 3745 Menu window, click on the MOSS Console option.
A MOSS window is displayed. Enter the PEM command on this window, and press Enter.
On the same window enter the SD (Super Diagnostic) function and press Enter.
On the Super Diagnostic window, select function 5 (transfer file to MOSS-E).
Enter the file names to be transferred as specified hereafter and press Enter.
– CHGCDF for CDF
– CHGCIL for BERs
For other dump files, type DDD in menu 3 to check their availability :
– CHGDMP
– CHHDMPA
– CHHDMPB
– CHGTRSSA
– CHGTRSSB
– CHGCADSA
– CHGCADSB
Enter PEM and press Enter to end.
Logon on the Remote Service Processor
Note
Before continuing, establish the physical connection with the local service processor.
On the desk top screen, double-click on the Distributed Console Access Facility icon.
A Distributed Console Access Facility-Icon View is displayed.
Double-click on the Controlling for the DCAF option.
On the Product Information window, click on OK.
On the Distributed Console Access Facility, click on Services in the action bar.
1-58
3745 Models 130 to 17A: MIP
Summary of Contents for 3745 130
Page 2: ......
Page 10: ...viii 3745 Models 130 to 17A MIP ...
Page 16: ...xiv 3745 Models 130 to 17A MIP ...
Page 23: ...Safety Figure 0 2 Ground Wire Connection on Controller Expansion Safety xxi ...
Page 46: ...Safety xliv 3745 Models 130 to 17A MIP ...
Page 47: ...Safety Safety xlv ...
Page 48: ...Safety xlvi 3745 Models 130 to 17A MIP ...
Page 49: ...Safety Safety xlvii ...
Page 50: ...Safety xlviii 3745 Models 130 to 17A MIP ...
Page 51: ...Safety Safety xlix ...
Page 52: ...Safety l 3745 Models 130 to 17A MIP ...
Page 53: ...Safety Safety li ...
Page 54: ...Safety lii 3745 Models 130 to 17A MIP ...
Page 55: ...Safety Safety liii ...
Page 56: ...Safety liv 3745 Models 130 to 17A MIP ...
Page 57: ...Safety Safety lv ...
Page 58: ...Safety lvi 3745 Models 130 to 17A MIP ...
Page 66: ...Safety lxiv 3745 Models 130 to 17A MIP ...
Page 68: ...Preface lxvi 3745 Models 130 to 17A MIP ...
Page 70: ...Amendments lxviii 3745 Models 130 to 17A MIP ...
Page 154: ...3745 MAPs 1 84 3745 Models 130 to 17A MIP ...
Page 200: ...Service Processor MAPs 2 46 3745 Models 130 to 17A MIP ...
Page 226: ...Diagnostics 3 26 3745 Models 130 to 17A MIP ...
Page 253: ...FRU Exchange Location 01S Figure 4 31 3745 EPO Chapter 4 3745 FRU Exchange 4 27 ...
Page 332: ...CE leaving procedure 4 106 3745 Models 130 to 17A MIP ...
Page 338: ...Maintenance Aids A 6 3745 Models 130 to 17A MIP ...
Page 354: ...Abbreviation X 6 3745 Models 130 to 17A MIP ...
Page 359: ......
Page 360: ...IBM Part Number 03F5017 Printed in Denmark by IBM Danmark A S ð3F5ð17 SY33 2ð7ð ð9 ...