3745 Panel Codes
Table
1-5 (Page 7 of 33). Panel Codes. An
ñ
following a panel code denotes that the code should 'Blink'.
Panel
Code
Definition
Action: Go to “3745 FRU Group
Table” on page 1-49
or to MAP number
11D
ñ
ERROR IN SSB BYTE 1 AND 2 READ/WRITE A
SECTOR COMMAND
Exchange the FRU group 16
11E
ñ
ADAPTER IN BUSY STATE IN TEST 10 BSTAT BITS
0,1 ARE NOT B'00' OR ADAPTER NOT ENABLE
BSTAT BIT 6 IS NOT ONE READ/WRITE A FULL
TRACK COMMAND
11F
ñ
IOIRV REGISTER IS X'00' IN TEST 10 NO INTER-
RUPT RECEIVED READ/WRITE A FULL TRACK
COMMAND
120
ñ
EIRV REGISTER IS NOT X'00' IN TEST 10
READ/WRITE A FULL TRACK COMMAND
121
ñ
DATA TRANSMISSION ERROR HSTAT BITS
0,1,2,3,6,7 ARE NOT ZERO READ/WRITE A FULL
TRACK COMMAND
Exchange the FRU group 16
122
ñ
DIFFERENT WRITTEN AND READ TRACKS
READ/WRITE A FULL TRACK COMMAND
123
ñ
ERROR IN SSB BYTE 0 READ/WRITE A FULL
TRACK COMMAND
124
ñ
ERROR IN SSB BYTE 1 AND 2 READ/WRITE A FULL
TRACK COMMAND
125
ñ
ADAPTER IN BUSY STATE IN TEST 11 BSTAT BITS
0,1 ARE NOT B'00' OR ADAPTER NOT ENABLE
BSTAT BIT 6 IS NOT ONE READ/WRITE NO DATA
COMMAND
Exchange the FRU group 16
126
ñ
IOIRV REGISTER IS X'00' IN TEST 11 NO INTER-
RUPT RECEIVED READ/WRITE NO DATA
COMMAND
127
ñ
EIRV REGISTER IS NOT X'00' IN TEST 11
READ/WRITE NO DATA COMMAND
128
ñ
DATA TRANSMISSION ERROR HSTAT BITS
0,1,2,3,6,7 ARE NOT ZERO READ/WRITE NO DATA
COMMAND
129
ñ
DIFFERENT WRITTEN AND READ SECTORS
READ/WRITE NO DATA COMMAND
Exchange the FRU group 16
12A
ñ
ERROR IN SSB BYTE 0 READ/WRITE NO DATA
COMMAND
12B
ñ
ERROR IN SSB BYTE 1 AND 2 READ/WRITE NO
DATA COMMAND
12C
ñ
ADAPTER IN BUSY STATE IN TEST 12 BSTAT BITS
0,1 ARE NOT B'00' OR ADAPTER NOT ENABLE
BSTAT BIT 6 IS NOT ONE READ CHECK/WRITE
VERIFY COMMAND
12D
ñ
IOIRV REGISTER IS X'00' IN TEST 12 NO INTER-
RUPT RECEIVED READ CHECK/WRITE VERIFY
COMMAND
Exchange the FRU group 16
12E
ñ
EIRV REGISTER IS NOT X'00' IN TEST 12 READ
CHECK/WRITE VERIFY COMMAND
12F
ñ
DATA TRANSMISSION ERROR HSTAT BITS
0,1,2,3,6,7 ARE NOT ZERO READ CHECK/WRITE
VERIFY COMMAND
130
ñ
ERROR IN SSB BYTE 0 READ CHECK/WRITE
VERIFY COMMAND
131
ñ
ERROR IN SSB BYTE 1 AND 2 READ CHECK/WRITE
VERIFY COMMAND
Exchange the FRU group 16
132
ñ
DIFFERENT WRITTEN AND READ SECTORS READ
CHECK/WRITE VERIFY COMMAND
133
ñ
ADAPTER IN BUSY STATE IN TEST 13 BSTAT BITS
0,1 ARE NOT B'00' OR ADAPTER NOT ENABLE
BSTAT BIT 6 IS NOT ONE ECC CORRECTION TEST
134
ñ
IOIRV REGISTER IS X'00' IN TEST 13 NO INTER-
RUPT RECEIVED ECC CORRECTION TEST
Chapter 1. START: How to Begin Troubleshooting
1-21
Summary of Contents for 3745 130
Page 2: ......
Page 10: ...viii 3745 Models 130 to 17A MIP ...
Page 16: ...xiv 3745 Models 130 to 17A MIP ...
Page 23: ...Safety Figure 0 2 Ground Wire Connection on Controller Expansion Safety xxi ...
Page 46: ...Safety xliv 3745 Models 130 to 17A MIP ...
Page 47: ...Safety Safety xlv ...
Page 48: ...Safety xlvi 3745 Models 130 to 17A MIP ...
Page 49: ...Safety Safety xlvii ...
Page 50: ...Safety xlviii 3745 Models 130 to 17A MIP ...
Page 51: ...Safety Safety xlix ...
Page 52: ...Safety l 3745 Models 130 to 17A MIP ...
Page 53: ...Safety Safety li ...
Page 54: ...Safety lii 3745 Models 130 to 17A MIP ...
Page 55: ...Safety Safety liii ...
Page 56: ...Safety liv 3745 Models 130 to 17A MIP ...
Page 57: ...Safety Safety lv ...
Page 58: ...Safety lvi 3745 Models 130 to 17A MIP ...
Page 66: ...Safety lxiv 3745 Models 130 to 17A MIP ...
Page 68: ...Preface lxvi 3745 Models 130 to 17A MIP ...
Page 70: ...Amendments lxviii 3745 Models 130 to 17A MIP ...
Page 154: ...3745 MAPs 1 84 3745 Models 130 to 17A MIP ...
Page 200: ...Service Processor MAPs 2 46 3745 Models 130 to 17A MIP ...
Page 226: ...Diagnostics 3 26 3745 Models 130 to 17A MIP ...
Page 253: ...FRU Exchange Location 01S Figure 4 31 3745 EPO Chapter 4 3745 FRU Exchange 4 27 ...
Page 332: ...CE leaving procedure 4 106 3745 Models 130 to 17A MIP ...
Page 338: ...Maintenance Aids A 6 3745 Models 130 to 17A MIP ...
Page 354: ...Abbreviation X 6 3745 Models 130 to 17A MIP ...
Page 359: ......
Page 360: ...IBM Part Number 03F5017 Printed in Denmark by IBM Danmark A S ð3F5ð17 SY33 2ð7ð ð9 ...