MAP 3530: Activate/Deactivate Line Problems or Line Errors on the
HPTSS/ESS
Symptom Explanation
Conditions That Could Cause This Symptom
You are unable to activate or deac-
tivate a line, or errors are occurring
while lines are running.
See below
001
– Ensure that the customer has completed his
Problem Determination guide procedure.
If not done, follow this problem determination
procedure yourself before continuing this map.
Does the problem still exist?
Yes No
002
– Problem is solved.
003
– Using the 3745 console, determine the number
of the line adapter driving the suspected line as
follows:
1. From Menu 3, select the TSS services by
entering TSS in the selection area.
2. From the TSS services screen, choose
select/release by entering 1 in the selection
area.
3. On the displayed select/release screen,
enter the address of the suspected line.
The line adapter number will be displayed in
the machine status area (MSA) and in the
selection area.
4. Enter REL in the input area to release the
line adapter.
Does the operator accept to deactivate all the
lines attached to this adapter?
Yes No
004
Go to Step 009.
005
– Go to “Disabling Procedure 0120: Preparing a
TSS/HPTSS/ESS for Maintenance” on
page 1-62 and follow the procedure until you
have run the HPTSS/ESS diagnostics for this
line adapter. Then return here.
Did the diagnostics run error free?
Yes No
006
Diagnostics have detected an error. With
the diagnostic reference code, go to “Diag-
nostic and Exchange Result Analysis 0000”
on page 4-99.
007
– Replace the modem cable on the failing port by
the wrap plug (PN 58X9349 for V.35, PN
58X9354 for X.21, or PN 70X8670 for ESS).
– Update the CDF. Run the VI and VK for V.35,
VJ and VK for X.21, or UF02 and UF03 for ESS
routines of the HPTSS or ESS diagnostics.
– Return here.
Did the diagnostics run error free?
Yes No
008
Diagnostics have detected an error. With
the diagnostic reference code, go to “Diag-
nostic and Exchange Result Analysis 0000”
on page 4-99.
009
The problem has not been resolved, collect any
related RECMS (MDR) records and contact your
support structure for assistance. Refer to “Con-
tacting Support” on page A-1.
Chapter 2. Map for FRU Isolation
2-9
Summary of Contents for 3745 130
Page 2: ......
Page 10: ...viii 3745 Models 130 to 17A MIP ...
Page 16: ...xiv 3745 Models 130 to 17A MIP ...
Page 23: ...Safety Figure 0 2 Ground Wire Connection on Controller Expansion Safety xxi ...
Page 46: ...Safety xliv 3745 Models 130 to 17A MIP ...
Page 47: ...Safety Safety xlv ...
Page 48: ...Safety xlvi 3745 Models 130 to 17A MIP ...
Page 49: ...Safety Safety xlvii ...
Page 50: ...Safety xlviii 3745 Models 130 to 17A MIP ...
Page 51: ...Safety Safety xlix ...
Page 52: ...Safety l 3745 Models 130 to 17A MIP ...
Page 53: ...Safety Safety li ...
Page 54: ...Safety lii 3745 Models 130 to 17A MIP ...
Page 55: ...Safety Safety liii ...
Page 56: ...Safety liv 3745 Models 130 to 17A MIP ...
Page 57: ...Safety Safety lv ...
Page 58: ...Safety lvi 3745 Models 130 to 17A MIP ...
Page 66: ...Safety lxiv 3745 Models 130 to 17A MIP ...
Page 68: ...Preface lxvi 3745 Models 130 to 17A MIP ...
Page 70: ...Amendments lxviii 3745 Models 130 to 17A MIP ...
Page 154: ...3745 MAPs 1 84 3745 Models 130 to 17A MIP ...
Page 200: ...Service Processor MAPs 2 46 3745 Models 130 to 17A MIP ...
Page 226: ...Diagnostics 3 26 3745 Models 130 to 17A MIP ...
Page 253: ...FRU Exchange Location 01S Figure 4 31 3745 EPO Chapter 4 3745 FRU Exchange 4 27 ...
Page 332: ...CE leaving procedure 4 106 3745 Models 130 to 17A MIP ...
Page 338: ...Maintenance Aids A 6 3745 Models 130 to 17A MIP ...
Page 354: ...Abbreviation X 6 3745 Models 130 to 17A MIP ...
Page 359: ......
Page 360: ...IBM Part Number 03F5017 Printed in Denmark by IBM Danmark A S ð3F5ð17 SY33 2ð7ð ð9 ...