3745 Panel Codes
Table
1-5 (Page 6 of 33). Panel Codes. An
ñ
following a panel code denotes that the code should 'Blink'.
Panel
Code
Definition
Action: Go to “3745 FRU Group
Table” on page 1-49
or to MAP number
0F7
ñ
EIRV REGISTER IS NOT X'00' IN TEST 7 READ ID
COMMAND TEST
Exchange the FRU group 16
0F8
ñ
DATA TRANSMISSION ERROR HSTAT BITS
0,1,2,3,6,7 ARE NOT ZERO READ ID COMMAND
TEST
0F9
ñ
ERROR ON HEAD ADDRESSING MECHANISM READ
ID COMMAND TEST
0FA
ñ
ERROR IN SSB BYTE 0 READ ID COMMAND TEST
0FB
ñ
ERROR IN SSB BYTE 1 AND 2 READ ID COMMAND
TEST
Exchange the FRU group 16
0FC
ñ
ADAPTER IN BUSY STATE IN TEST 8 BSTAT BITS
0,1 ARE NOT B'00' OR ADAPTER NOT ENABLE
BSTAT BIT 6 IS NOT ONE RECALIBRATE COMMAND
BEFORE SEEK TEST
0FD
ñ
IOIRV REGISTER IS X'00' IN TEST 8 NO INTER-
RUPT RECEIVED RECALIBRATE COMMAND
BEFORE SEEK TEST
0FE
Unused
Go to “MAP 3220: Undefined Panel
Message” on page 2-5
0FF
ñ
ADAPTER IN BUSY STATE IN TEST 8 BSTAT BITS
0,1 ARE NOT B'00' OR ADAPTER NOT ENABLE
BSTAT BIT 6 IS NOT ONE SEEK COMMAND TEST
Exchange the FRU group 16
100
Unused
Go to “MAP 3220: Undefined Panel
Message” on page 2-5
101
HARD DISK INITIAL STATE IS NOT OK. A
RECOVERY PROCEDURE IS RUNNING.
Exchange the FRU group 16
102
HARD DISK INITIAL STATE NOT OK (EVEN AFTER
A RECOVERY PROCEDURE).
103 to 110
Unused
Go to “MAP 3220: Undefined Panel
Message” on page 2-5
111
ñ
IOIRV REGISTER IS X'00' IN TEST 8 NO INTER-
RUPT RECEIVED SEEK COMMAND TEST
Exchange the FRU group 16
112
ñ
EIRV REGISTER IS NOT X'00' IN TEST 8 SEEK
COMMAND TEST
113
ñ
DATA TRANSMISSION ERROR HSTAT BITS
0,1,2,3,6,7 ARE NOT ZERO SEEK COMMAND TEST
114
ñ
DIFFERENT HEAD NUMBERS SEEK COMMAND
TEST
115
ñ
ERROR IN SSB BYTE 0 SEEK COMMAND TEST
Exchange the FRU group 16
116
ñ
ERROR IN SSB BYTE 1 AND 2 SEEK COMMAND
TEST
117
ñ
ADAPTER IN BUSY STATE IN TEST 9 BSTAT BITS
0,1 ARE NOT B'00' OR ADAPTER NOT ENABLE
BSTAT BIT 6 IS NOT ONE READ/WRITE A SECTOR
COMMAND
118
ñ
IOIRV REGISTER IS X'00' IN TEST 9 NO INTER-
RUPT RECEIVED READ/WRITE A SECTOR
COMMAND
119
ñ
EIRV REGISTER IS NOT X'00' IN TEST 9
READ/WRITE A SECTOR COMMAND
Exchange the FRU group 16
11A
ñ
DATA TRANSMISSION ERROR HSTAT BITS
0,1,2,3,6,7 ARE NOT ZERO READ/WRITE A SECTOR
COMMAND
11B
ñ
DIFFERENT WRITTEN AND READ SECTORS
READ/WRITE A SECTOR COMMAND
11C
ñ
ERROR IN SSB BYTE 0 READ/WRITE A SECTOR
COMMAND
1-20
3745 Models 130 to 17A: MIP
Summary of Contents for 3745 130
Page 2: ......
Page 10: ...viii 3745 Models 130 to 17A MIP ...
Page 16: ...xiv 3745 Models 130 to 17A MIP ...
Page 23: ...Safety Figure 0 2 Ground Wire Connection on Controller Expansion Safety xxi ...
Page 46: ...Safety xliv 3745 Models 130 to 17A MIP ...
Page 47: ...Safety Safety xlv ...
Page 48: ...Safety xlvi 3745 Models 130 to 17A MIP ...
Page 49: ...Safety Safety xlvii ...
Page 50: ...Safety xlviii 3745 Models 130 to 17A MIP ...
Page 51: ...Safety Safety xlix ...
Page 52: ...Safety l 3745 Models 130 to 17A MIP ...
Page 53: ...Safety Safety li ...
Page 54: ...Safety lii 3745 Models 130 to 17A MIP ...
Page 55: ...Safety Safety liii ...
Page 56: ...Safety liv 3745 Models 130 to 17A MIP ...
Page 57: ...Safety Safety lv ...
Page 58: ...Safety lvi 3745 Models 130 to 17A MIP ...
Page 66: ...Safety lxiv 3745 Models 130 to 17A MIP ...
Page 68: ...Preface lxvi 3745 Models 130 to 17A MIP ...
Page 70: ...Amendments lxviii 3745 Models 130 to 17A MIP ...
Page 154: ...3745 MAPs 1 84 3745 Models 130 to 17A MIP ...
Page 200: ...Service Processor MAPs 2 46 3745 Models 130 to 17A MIP ...
Page 226: ...Diagnostics 3 26 3745 Models 130 to 17A MIP ...
Page 253: ...FRU Exchange Location 01S Figure 4 31 3745 EPO Chapter 4 3745 FRU Exchange 4 27 ...
Page 332: ...CE leaving procedure 4 106 3745 Models 130 to 17A MIP ...
Page 338: ...Maintenance Aids A 6 3745 Models 130 to 17A MIP ...
Page 354: ...Abbreviation X 6 3745 Models 130 to 17A MIP ...
Page 359: ......
Page 360: ...IBM Part Number 03F5017 Printed in Denmark by IBM Danmark A S ð3F5ð17 SY33 2ð7ð ð9 ...