Diagnostics
How to Run the LIC Wrap Test with IFTs
Install the Wrap Plug:
For HPTSS
Install the wrap plug PN 58X9349 for V35 or
PN 58X9354 for X.21 on the tailgate con-
nector.
For ESS
Install the wrap plug PN 70X8670 on the
tailgate connector.
For LIC Types 1 and 4
Install the wrap plug PN 65X8927 on the LIC
connector. See Figure 3-8 and Figure 3-10
on page 3-23.
For LIC Type 3
Install the wrap cable PN 65X8928 between
the two sockets. See Figure 3-9 and
Figure 3-10 on page 3-23.
Notes:
1. To fully test the port (all control leads)
install the wrap cable and run the test.
2. Reverse the wrap cable ends (between
the DCE and direct attach connector).
3. Repeat the test.
For LIC Types 5 and 6
1. Unplug the line cable at the customer wall
frame.
2. Install the appropriate wrap plug (see fol-
lowing list) at the end of the cable or
unplug the line cable from both ends.
3. Install the wrap plug PN 11F4815 at the
tail gate connector (the line cable must be
unplugged from wall frame for line loading
reasons.). See Figure 3-11 and
Figure 3-12 on page 3-24.
LIC Types 5 and 6 Wrap Plug Country Part
Number
Country
Part Number
Austria
6162946
Belgium
6162950
France
6162955
Germany
6162950
Hong Kong
65X8070
Israel
66X1954
Italy
6162957
Japan
6124644
Luxemburg
6162950
Netherlands
6162948
Switzerland
66X0748
U.K.
65X8069
U.S.A./Canada
66X0807
Start the Diagnostic
For HPTSS
1. Update the CDF to indicates that the lines
to be tested have wrap plugs installed.
Refer to
IBM 3745 Service Functions.
2. Using “How to Run Internal Function
Tests” on page 3-9, enter the following:
a. Diagnostic group 7 in the DIAG==>
area.
b. Adapter number in the
ADP#==> area.
3. Press SEND.
For ESS
1. Using “How to Run Internal Function
Tests” on page 3-9 enter the following:
a. Diagnostic group 9 in the DIAG==>
area.
b. Adapter number in the
ADP#==> area.
2. Press SEND.
For LIC Types 1, 3, and 4
Using “How to Run Internal Function Tests” on
page 3-9, enter the following:
1. Routine number RC01 in the
DIAG==> area.
2. Adapter number in the
ADP#==> area.
3. Line number in the LINE==> area. You
may obtain the line number from the LID
function (in Menu 1) by entering the line
address.
4. Press SEND.
For LIC Types 5, and 6
Using “How to Run Internal Function Tests” on
page 3-9 enter the following :
1. Routine number RH59 in the
DIAG==> area.
2. Adapter number in the ADP#==> area.
Chapter 3. How to Run 3745 Diagnostics
3-13
Summary of Contents for 3745 130
Page 2: ......
Page 10: ...viii 3745 Models 130 to 17A MIP ...
Page 16: ...xiv 3745 Models 130 to 17A MIP ...
Page 23: ...Safety Figure 0 2 Ground Wire Connection on Controller Expansion Safety xxi ...
Page 46: ...Safety xliv 3745 Models 130 to 17A MIP ...
Page 47: ...Safety Safety xlv ...
Page 48: ...Safety xlvi 3745 Models 130 to 17A MIP ...
Page 49: ...Safety Safety xlvii ...
Page 50: ...Safety xlviii 3745 Models 130 to 17A MIP ...
Page 51: ...Safety Safety xlix ...
Page 52: ...Safety l 3745 Models 130 to 17A MIP ...
Page 53: ...Safety Safety li ...
Page 54: ...Safety lii 3745 Models 130 to 17A MIP ...
Page 55: ...Safety Safety liii ...
Page 56: ...Safety liv 3745 Models 130 to 17A MIP ...
Page 57: ...Safety Safety lv ...
Page 58: ...Safety lvi 3745 Models 130 to 17A MIP ...
Page 66: ...Safety lxiv 3745 Models 130 to 17A MIP ...
Page 68: ...Preface lxvi 3745 Models 130 to 17A MIP ...
Page 70: ...Amendments lxviii 3745 Models 130 to 17A MIP ...
Page 154: ...3745 MAPs 1 84 3745 Models 130 to 17A MIP ...
Page 200: ...Service Processor MAPs 2 46 3745 Models 130 to 17A MIP ...
Page 226: ...Diagnostics 3 26 3745 Models 130 to 17A MIP ...
Page 253: ...FRU Exchange Location 01S Figure 4 31 3745 EPO Chapter 4 3745 FRU Exchange 4 27 ...
Page 332: ...CE leaving procedure 4 106 3745 Models 130 to 17A MIP ...
Page 338: ...Maintenance Aids A 6 3745 Models 130 to 17A MIP ...
Page 354: ...Abbreviation X 6 3745 Models 130 to 17A MIP ...
Page 359: ......
Page 360: ...IBM Part Number 03F5017 Printed in Denmark by IBM Danmark A S ð3F5ð17 SY33 2ð7ð ð9 ...