Panel
Code
Definition
Action: Go to “3745 FRU Group
Table” on page 1-49
or to MAP number
A38
ñ
Moss level 0 error detection; MCCU A; PIO; Timeout;
Outbound address parity check
Exchange the FRU group 20
A39
ñ
Moss level 0 error detection; MCCU A; PIO; Timeout;
Adapter not detected
A3A
ñ
Moss level 0 error detection; MCCU A; PIO; Timeout;
Adapter failure
A3B
ñ
Moss level 0 error detection; MCCU A; PIO; Timeout;
Multiple bits detected in Stat reg
A3C to A67
Unused
Go to “MAP 3220: Undefined Panel
Message” on page 2-5
A68
ñ
Moss level 0 error detection; SWAD; Adapter is 'down'
Exchange the FRU group 5
A69
ñ
Moss level 0 error detection; SWAD; Adapter is 'down';
Excess spurious errors
A6A
ñ
Moss level 0 error detection; SWAD; Adapter check;
Internal clock check 1
A6B
ñ
Moss level 0 error detection; SWAD; Adapter check;
Internal clock check 2
A6C
ñ
Moss level 0 error detection; SWAD; Adapter check;
Multiple bits detected in Disconnect reg
Exchange the FRU group 5
A6D
ñ
Moss level 0 error detection; SWAD; Device; Adapter
check; State counter parity
A6E
ñ
Moss level 0 error detection; SWAD; Device; Adapter
check; Shift pulse counter parity
A6F
ñ
Moss level 0 error detection; SWAD; Device; Adapter
check; Ground fault detected on a driver line
A70
ñ
Moss level 0 error detection; SWAD; Device; Adapter
check; Interface check
Exchange the FRU group 5
A71
ñ
Moss level 0 error detection; SWAD; Device; Adapter
check; Interface timeout
A72
ñ
Moss level 0 error detection; SWAD; Device; Adapter
check; Interface parity check
A73
ñ
Moss level 0 error detection; SWAD; Device; Adapter
check; Multiple bits detected in EB Stat reg
A74
ñ
Moss level 0 error detection; SWAD; Device; Adapter
check; Switch interface error
Exchange the FRU group 5
A75
ñ
Moss level 0 error detection; SWAD; Device; Adapter
check; Switch driver fault
A76
ñ
Moss level 0 error detection; SWAD; Device; Adapter
check; Switch serial link parity
A77
ñ
Moss level 0 error detection; SWAD; Device; Adapter
check; Switch invalid command
A78
ñ
Moss level 0 error detection; SWAD; Device; Adapter
check; Multiple bits detected in Device stat reg
Exchange the FRU group 5
A79
ñ
Moss level 0 error detection; SWAD; Device; Adapter
check; Adapter failure
A7A
ñ
Moss level 0 error detection; SWAD; Device; Adapter
check; No Common Adapter Code running
A7B
ñ
Moss level 0 error detection; SWAD; PIO; Bus check;
Inbound parity
A7C
ñ
Moss level 0 error detection; SWAD; PIO; Bus check;
Adapter failure
Exchange the FRU group 5
A7D
ñ
Moss level 0 error detection; SWAD; PIO; Bus check;
Adapter not detected
A7E
ñ
Moss level 0 error detection; SWAD; PIO; Timeout;
Invalid command
A7F
ñ
Moss level 0 error detection; SWAD; PIO; Timeout;
Outbound address parity check
1-28
3745 Models 130 to 17A: MIP
Summary of Contents for 3745 130
Page 2: ......
Page 10: ...viii 3745 Models 130 to 17A MIP ...
Page 16: ...xiv 3745 Models 130 to 17A MIP ...
Page 23: ...Safety Figure 0 2 Ground Wire Connection on Controller Expansion Safety xxi ...
Page 46: ...Safety xliv 3745 Models 130 to 17A MIP ...
Page 47: ...Safety Safety xlv ...
Page 48: ...Safety xlvi 3745 Models 130 to 17A MIP ...
Page 49: ...Safety Safety xlvii ...
Page 50: ...Safety xlviii 3745 Models 130 to 17A MIP ...
Page 51: ...Safety Safety xlix ...
Page 52: ...Safety l 3745 Models 130 to 17A MIP ...
Page 53: ...Safety Safety li ...
Page 54: ...Safety lii 3745 Models 130 to 17A MIP ...
Page 55: ...Safety Safety liii ...
Page 56: ...Safety liv 3745 Models 130 to 17A MIP ...
Page 57: ...Safety Safety lv ...
Page 58: ...Safety lvi 3745 Models 130 to 17A MIP ...
Page 66: ...Safety lxiv 3745 Models 130 to 17A MIP ...
Page 68: ...Preface lxvi 3745 Models 130 to 17A MIP ...
Page 70: ...Amendments lxviii 3745 Models 130 to 17A MIP ...
Page 154: ...3745 MAPs 1 84 3745 Models 130 to 17A MIP ...
Page 200: ...Service Processor MAPs 2 46 3745 Models 130 to 17A MIP ...
Page 226: ...Diagnostics 3 26 3745 Models 130 to 17A MIP ...
Page 253: ...FRU Exchange Location 01S Figure 4 31 3745 EPO Chapter 4 3745 FRU Exchange 4 27 ...
Page 332: ...CE leaving procedure 4 106 3745 Models 130 to 17A MIP ...
Page 338: ...Maintenance Aids A 6 3745 Models 130 to 17A MIP ...
Page 354: ...Abbreviation X 6 3745 Models 130 to 17A MIP ...
Page 359: ......
Page 360: ...IBM Part Number 03F5017 Printed in Denmark by IBM Danmark A S ð3F5ð17 SY33 2ð7ð ð9 ...