441
Appendi
x
(In the panel window, the three digits after “E” indicate an error number.)
Error No.
Error name
Description, action, etc.
B00
SCHA setting error
The setting value of SCHA command is invalid.
B01
TPCD setting error
The setting value of TPCD command is invalid.
B02
SLEN setting error
The setting value of SLEN command is invalid.
B03
Home-return method error
The setting value of “Axis-specific parameter No. 10, Home-return method” is
invalid. (Not incremental encoder AND current position 0 home is specified, etc.)
B04
1-shot-pulse output excessive simultaneous use error
The number of BTPN and BTPF timers operating in one program simultaneously
exceeds the upper limit (16).
B05
Estimate-stroke over error at home return
The operation at home return exceeded the estimate stroke. The home sensor or
creep sensor may be faulty, among other reasons.
B10
Phase-Z search timeout error
Phase Z cannot be detected. Check for operation restriction, wiring, encoder,
motor, etc.
B11
Home-sensor pull-out timeout error
Pull-out from the home sensor cannot be confirmed. Check for operation
restriction, wiring, motor, home sensor, etc.
B12
Storage variable number error for SEL command return code
The variable number specified for storing SEL command’s return code is invalid.
B13
Backup SRAM data checksum error
The backup SRAM data has been destroyed. Check the battery.
B15
Input-port debug filter type error
The setting value of input-port debug filter type is invalid.
B16
SEL operand specification error
The operand specification of SEL command is invalid.
B17
Parameter register busy error at issuance of slave command
The driver special command ACK generated a timeout at issuance of a slave
command.
B18
Device number error
The device number is invalid.
B19
Unit type error
The unit type is invalid
B1A
Absolute reset specification error
The specification for absolute reset using an optional function, etc., is invalid.
(Two or more axes are specified simultaneously, non-absolute-encoder axis is
specified, etc.)
B86
SEL PTRQ command preprocessing error
The PTRQ command setting ivalue s abnormal. Check the setting value for
abnormality, such as deviation from the allowable range.
B92
Excessive arc interpolation radius error
The radius for arc interpolation is too large. Use CIR, ARC or other command.
C02
Executable program count over error
Execution requests were received for programs exceeding the number that can
be executed simultaneously.
C03
Non-registered program specification error
The specified program is not registered.
C04
Program entry point non-detection error
A request was made to execute a program number for which no program steps
are registered.
C05
Program first-step BGSR error
The program specified for execution starts with BGSR.
C06
Executable step non-detection error
The program specified for execution does not contain executable program steps.
C07
Subroutine non-definition error
The subroutine specified for call is not defined.
C08
Subroutine duplicate-definition error
The same subroutine number is defined at multiple locations.
C0A
Tag duplicate-definition error
The same tag number is defined at multiple locations.
C0B
Tag non-definition error
The tag specified as the jump destination of a GOTO statement is not defined.