244
Part 2 Programs
1.24 Building of Pseudo-Ladder Task
CHPR (Change task level)
Command, declaration
Extension condition
(LD, A, O, AB, OB)
Input condition
(I/O, flag)
Command,
declaration
Operand 1
Operand 2
Output
(Output, flag)
Optional
Optional
CHPR
0 or 1
Prohibited
CP
[Function] Specify “1” (User HIGH) if you wish the target task to be processed before other tasks.
This command can also be used with non-ladder tasks.
Task level change (0: User NORMAL, 1: User HIGH) is not a required component, but
specifying User HIGH will require a TSLP command explained below. (Without TSLP, tasks of
the User NORMAL level will not be processed.)
TPCD (Specify processing to be performed when input condition is not specified)
Command, declaration
Extension condition
(LD, A, O, AB, OB)
Input condition
(I/O, flag)
Command,
declaration
Operand 1
Operand 2
Output
(Output, flag)
Prohibited Prohibited TPCD 0 or 1
Prohibited
CP
[Function] Specify the processing to be performed when input condition is not specified.
(0: Execute, 1: Follow the input condition in the last executed step)
In a ladder task, always input “1” (Follow the input condition in the last executed step) in
operand 1.
In a non-ladder task, always input “0” (Execute). (The default value is “0.”)