456
Appendi
x
(In the panel window, the three digits after “E” indicate an error number.)
Error No.
Error name
Description, action, etc.
E59
Brake ON/OFF timeout error
Brake ON/OFF cannot be confirmed.
E5A
Pole sense non-detection error
Motor magnetic pole cannot be detected.
E5B
Detection OFF error upon pole sense completion
The motor-magnetic-pole detection status bit (Psenex) is turned OFF after
completion of pole sense.
E5C
Hold-at-stop servo job error
The servo job is invalid.
E5D
Servo packet error
The servo packets are invalid.
E5E
Servo-control-right management array number error
The servo-control-right management array number is invalid.
E5F
Length conversion parameter error
Check axis-specific parameter Nos. 47, 50, 51, 42, 1, etc.
E60
Slave maximum receive size over error
The slave receive size is too large.
E61
Slave no normal response reception error
Normal response cannot be received from the slave.
E62
Sending-slave CPU type error
The CPU type of the sending slave is invalid.
E63
Message-buffer information type error
The message-buffer information type is invalid.
E64
Abnormal standby power detection error
Abnormal standby power was detected.
E65
Regenerative resistance temperature error
A regenerative resistance temperature error was detected.
E66
AC-power overvoltage error
An AC-power overvoltage error was detected.
E67
Motor-power overvoltage error
A motor-power overvoltage error was detected.
E68
Emergency-stop status requiring reset recovery (not error)
Reset the emergency stop and then reconnect the power.
E69
Abnormal 24-V I/O power source
The 24-V I/O power source is abnormal.
E6A
Safety-gate open status requiring reset recovery (not error)
Close the safety gate and then reconnect the power.
E6B
Shutdown factor indeterminable error
Shutdown factor cannot be determined.
E6C
DO output current error
The DO output current is abnormal.
E6D
Drive-source cutoff relay error
The drive-source cutoff relay may have been melted.
E71
Encoder configuration information outside supported function
information range
An encoder whose configuration information is outside the range supported by
the driver unit is installed.
E72
Motor configuration information outside supported function
information range
A motor whose configuration information is outside the range supported by the
driver unit is installed.
E73
Encoder resolution mismatch error
The encoder resolution in the system’s axis-specific parameter and that of the
installed encoder do not match.
E74
Encoder division ratio mismatch error
The encoder division ratio in the system’s axis-specific parameter and that of the
installed encoder do not match.
E75
Encoder linear/rotary type mismatch error
The encoder linear/rotary type in the system’s axis-specific parameter and that of
the installed encoder do not match.
E76
Encoder ABS/INC type mismatch error
The encoder ABS/INC type in the system’s axis-specific parameter and that of
the installed encoder do not match.