411
Appendix
Axis-Specific Parameters
No Parameter name
Default value
(Reference)
Input range
Unit
Remarks
56 Push-abort deviation ratio at
home return
2000
1 ~ 99999
Deviation is compared against “Steady-state deviation of
push speed + Push-speed pulse speed x Abort deviation
ratio.”
57 Push-abort deviation ratio at
positioning
5000 1
~
99999
Deviation is compared against “Steady-state deviation of
push speed + Push-speed pulse speed x Abort deviation
ratio.”
58 Positioning band
100
1 ~ 9999
0.001 mm
59 Allowable
deviation
error
ratio
(Maximum speed pulse
ratio)
85
1 ~ 9999
Deviation is compared against “Steady-state deviation of
maximum operating speed of each axis + Pulse speed of
maximum operating speed of each axis x Allowable deviation
error ratio.”
60 Position gain
30
1 ~ 9999
/s
61 FAG
0
0
~
999
62 Synchro FB gain
77
0 ~ 1000
63 Stop special output range
1
0 ~ 9999
Pulse
Invalid if “0” is set.
64 Stop special output value
1
0 ~ 999
DRVVR
65 Mating synchro-axis number
0
0 ~ 8
Must be input for both axes. (Of the axis pair, the axis with
the smaller axis number becomes the master axis. Both axes
must have the same resolution characteristics. Commands
cannot be issued to the slave axis.) (Invalid if “0” is set)
66 Mode selection for rotational
movement axis
0
0 ~ 5
0: Normal, 1: Index mode
67 Short-cut control selection
for rotational movement axis
0
0 ~ 5
0: Do not select, 1: Select (Valid only in the index mode
AND when an incremental encoder is used)
68 Mode selection for linear
movement axis
0
0 ~ 5
0: Normal, 1: Infinite-stroke mode (Note: Positioning
boundary applies. This setting can be specified only when
an incremental encoder is used.)
69 (For
expansion)
0
~
70 For
future
expansion
0
Reference
only
71 For
future
expansion
0
Reference
only
72 DRVVR + offset
0
Reference
only
DRVVR
(Change prohibited) To maintain symmetry of the positive
and negative sides.
73 DRVVR – offset
0
Reference
only
DRVVR
(Change prohibited) To maintain symmetry of the positive
and negative sides.
74 For
future
expansion
0
Reference
only
75 For
future
expansion
0
Reference
only
76 Home-adjustment
parameter set selection
1 Reference
only
(Change
prohibited)
0: P21 = Phase-Z evacuation distance at INC home return
P12 = Ideal phase-Z position coordinate
1: P32 is read automatically even when P33 = 0. P33 = 0
indicates “actual distance.”
P21 = Offset travel at home return
P12 = Coordinate achieved by offset travel at home return
P26 = Invalid
(To facilitate adjustment)
77 Synchro S pulse
3
0 ~ 99999
Pulse
78 Maximum
takeoff
command
amount
0 -3000
~
3000
0.001 mm
Maximum lift command amount before brake unlock (Input
with sign)
(Suppression of momentary drop upon servo ON when a
heavy object is placed)
* Important: Input using the same sign as the rising
coordinate direction. (0.100 mm to 0.500 mm in absolute
value as a guideline)
* The servo-ON check time (axis-specific parameter No. 30)
must also be extended (approx. 1000 to 1500 msec) to
provide a sufficient time for rise-direction torque to follow.
(Valid only when installation of brake is specified.)
79 Actual takeoff check
distance
5
0 ~ 3000
0.001 mm
Absolute value input
80 Maximum forced-feed range
0
0 ~ 9999
0.001 mm
For reduction of settling time. (Invalid range if “0” is set)
(Approx. 1.000 mm as a guideline)
81 Minimum forced-feed range
200
0 ~ 9999
0.001 mm
82 Medium forced-feed range
600
0 ~ 9999
0.001 mm
Summary of Contents for ssel