![IAI ssel Operation Manual Download Page 174](http://html1.mh-extra.com/html/iai/ssel/ssel_operation-manual_604058174.webp)
148
Part 2 Programs
PVEL (Assign speed data)
Command, declaration
Extension condition
(LD, A, O, AB, OB)
Input condition
(I/O, flag)
Command,
declaration
Operand 1
Operand 2
Output
(Output, flag)
Optional Optional
PVEL
Speed
Position
number
CP
[Function] Write the speed specified in operand 1 to the position number specified in operand 2.
(Note)
If a negative value is written with a PVEL command, an alarm will generate when that position
is specified in a movement operation, etc. Exercise caution.
[Example 1]
PVEL
100
10
Write speed 100 mm/s to position No. 10.
[Example 2]
LET
1
100
Assign 100 to variable 1.
LET
2
10
Assign 10 to variable 2.
PVEL
*1
*2
Write the content of variable 1 (speed 100 mm/s) to the
content of variable 2 (position 10).