439
Appendi
x
(In the panel window, the three digits after “E” indicate an error number.)
Error No.
Error name
Description, action, etc.
A40
Data change refusal error during flash ROM write
Data cannot be changed while the flash ROM is being written.
A41
Duplicate flash-ROM write commands refusal error
Another flash-ROM write command was received while the flash ROM was being
written.
A42
Direct monitor prohibition error during flash ROM write
Direct monitor is prohibited while the flash ROM is being written.
A43
P0/P3-area direct monitor prohibition error
Direct monitor in the P0/P3 areas is prohibited.
A44
Point-data count specification error
The specified number of point data is invalid.
A45
Symbol-record count specification error
The specified number of symbol records is invalid.
A46
Variable-data count specification error
The specified number of variable data is invalid.
A48
Error-detail query type 1 error
Error-detail query type 1 is invalid.
A49
Error-detail query type 2 error
Error-detail query type 2 is invalid.
A4A
Monitoring data type error
The data type for monitoring data query is invalid.
A4B
Monitoring-record count specification error
The specified number of records for monitoring data query is invalid.
A4C
Monitoring-operation special command register busy error
The driver special command ACK generated a timeout during monitoring operation.
A4E
Parameter register busy error at issuance of slave command
The driver special command ACK generated a timeout at issuance of a slave
command.
A4F
Software reset refusal error during operation
Software reset (SIO) is prohibited during operation (program is running, servo is in
use, etc.).
A50
Drive-source recovery request refusal error
The drive-source cutoff factor (error, deadman switch, safety gate, emergency stop,
etc.) has not been removed.
A51
Operation-pause reset request refusal error The
all-operation-pause factor (drive-source cutoff, operation-pause signal, deadman
switch, safety gate, emergency stop, etc.) has not been removed.
A53
Refusal error due to servo ON
A processing not permitted during servo ON was attempted.
A54
Refusal error due to unsupported function
The function is not supported.
A55
Refusal error due to exclusive manufacturer function
A processing not opened to users other than the manufacturer was attempted.
A56
Refusal error due to invalid data
The data is invalid.
A57
Program start duplication error
An attempt was made to start a program currently running.
A58
BCD error warning
The BCD value being read may be invalid, or the value being written (variable 99)
may be a negative value, among other reasons.
A59
IN/OUT command port flag error warning
The number of I/O ports (flags) may have exceeded 32, among other reasons. Check
the I/O port (flag) specifications.
A5B
Character-string
value conversion error warning
The specified number of converting characters is invalid or characters that cannot be
converted to value are included.
A5C
Copying-character count error warning with SCPY command
The specified number of copying characters is invalid.
A5D
SCIF open error in non-AUTO mode
The channel was opened in a non-AUTO mode. In the MANU mode, the PC/TP
connection must be forcibly disconnected before opening the serial channel opened
to the user. Exercise caution.