172
Part 2 Programs
1.12 Actuator Control Command
SV
(Turn ON/OFF servo)
Command, declaration
Extension condition
(LD, A, O, AB, OB)
Input condition
(I/O, flag)
Command,
declaration
Operand 1
Operand 2
Output
(Output, flag)
Optional Optional
SV
Axis
pattern
Prohibited PE
[Function]
Turn ON/OFF the servos of the axes specified by the axis pattern in operand 1.
SV
ON
Turn ON the servo.
OF
Turn OFF the servo.
[Example 1]
SVON
11
Turn ON the servos of axes 1 and 2. Nothing will occur if the
axis servos are already ON.
[Example 2]
The axis pattern can be specified indirectly using a variable.
When the command in [Example 1] is rephrased based on indirect specification using
a variable:
11 (binary)
3 (decimal)
LET
1
3
Assign 3 to variable 1.
SVON
*1