149
Part 2 Programs
PACC (Assign acceleration data)
Command, declaration
Extension condition
(LD, A, O, AB, OB)
Input condition
(I/O, flag)
Command,
declaration
Operand 1
Operand 2
Output
(Output, flag)
Optional Optional
PACC
Acceleration
Position
number
CP
[Function] Write the acceleration specified in operand 1 to the position number specified in operand 2.
(Note)
Range check is not performed for a PACC command. Be careful not to exceed the limit set for
each actuator.
[Example 1]
PACC
0.3
10
Write acceleration 0.3 G to position No. 10.
[Example 2]
LET
100
0.3
Assign 0.3 to variable 100.
LET
2
10
Assign 10 to variable 2.
PACC
*100
*2
Write the content of variable 100 (acceleration 0.3 G) to the
content of variable 2 (position 10).