91
Part 2 Programs
(2) Axis
pattern
Whether or not each axis will be used is indicated by “1” or “0.”
(Upper) (Lower)
Axis number
Axis 2
Axis 1
Used 1 1
Not used
0
0
[Example]
When axes 1 and 2 are used
Axis 2
11
Axis 1
[Example]
When axes 2 is used
Axis 2
10 (In this case, the 0s are needed to indicate the position of axis 2.)
Indirect specification of axis pattern in a variable
The axis pattern is considered a binary value, and a converted decimal value is assigned to a variable.
[Example]
To perform home return for axis 2 only, you can specify as follows based on axis pattern:
HOME 10
In indirect specification, 10 (binary) is expressed as 2 (decimal), so the same operation can
be specified as follows:
LET
6 2
HOME *6
If you must select and specify multiple axes at the same time, use axis pattern.
Commands that use axis specification based on axis pattern
OFST, GRP, SVON, SVOF, HOME, JFWN, JFWF, JBWN, JBWF, STOP, PTST, PRED
CHVL, PBND, WZNA, WZNO, WZFA, WZFO, movd, MVDI,PTRQ