Chapter 7 Parameter
253
7.2 Detail Explanation of Parameters
Establish settings for each axis number.
Caution: •
If parameters are changed (writing), provide software reset or reconnect
the power to reflect the setting values.
•
The unit [deg] is for rotary actuator and lever type gripper. Pay attention
that it is displayed in mm in the teaching tools.
[1] Zone 1 positive side, zone 1 negative side (Parameter No.1, No.2)
Zone 2 positive side, zone 2 negative side (Parameter No.23, No.24)
No.
Name
Symbol
Unit
Input Range
Default factory
setting
1
Zone 1 Positive Side
ZNM1
mm
[deg]
-9999.99 to
9999.99
Actual stroke on
positive side
2
Zone 1 Negative Side
ZNL1
mm
[deg]
-9999.99 to
9999.99
Actual stroke on
negative side
23 Zone 2 Positive Side
ZNM2
mm
[deg]
-9999.99 to
9999.99
Actual stroke on
positive side
24 Zone 2 Negative Side
ZNL2
mm
[deg]
-9999.99 to
9999.99
Actual stroke on
negative side
These parameters are used to set the zone in which zone signal (ZONE1 or ZONE2) turns ON.
The minimum setting unit is 0.01 mm [deg].
If a specific value is set to both zone setting positive side and zone setting negative side, the
zone signal is not output.
A setting sample is shown below.
[Example of when line axis]
Current position
Zone signal output
Zone signal output
ON
ON
ON
0mm
100mm
70mm
30mm
Set Value
Zone setting positive side : 70mm
Zone setting negative side : 30mm
Set Value
Zone setting positive side : 30mm
Zone setting negative side : 70mm
[Example of Rotary Actuator Index Mode]
315°
0°
0°
315°
70°
70°
Zone signal ON range
Caution: The zone detection range would not output unless the value exceeds that of the
minimum resolution (actuator lead length / No. of Encoder Pluses).
ME0306-2A
Summary of Contents for MSCON
Page 1: ...MSCON Controller Instruction Manual Second Edition ...
Page 2: ......
Page 4: ...ME0306 2A ...
Page 8: ...ME0306 2A ...
Page 20: ...12 ME0306 2A ...
Page 28: ...20 ME0306 2A ...
Page 46: ...Chapter 1 Specifications Check 38 ME0306 2A ...
Page 240: ...3 11 Gateway status LED 232 ME0306 2A ...
Page 246: ...Chapter 4 Vibration Suppress Control Function 238 ME0306 2A ...
Page 290: ...Chapter 7 Parameter 282 ME0306 2A ...
Page 310: ...Chapter 8 Troubleshooting 302 ME0306 2A ...
Page 354: ...Chapter 9 Appendix 346 ME0306 2A ...
Page 358: ......
Page 359: ......