Chapter 1 Specifications Check
30
1.4.5 Specifications of EtherNet/IP Interface
Item
Specification
Communication Protocol
IEC61158 (IEEE802.3)
Baud Rate
10BASE-T/100BASE-T (Autonegotiation setting is recommended)
Communication Cable Length
EtherNet/IP Specifications (Distance between hub and each node: 100m or
less)
Number of Connection
Master Unit
Available Node Addresses for
Setting
0.0.0.0 to 255.255.255.255
Communications Cable
(Note1)
Category 5e or higher
(Double shielded cable braided with aluminum foil recommended)
Connector
RJ45 Connector × 1pc
Note1: Please prepare a communication cable separately.
1.4.6 Specifications of EtherCAT Interface
Item
Specification
Communication Protocol
IEC61158 type12
Physical Layer
100Base-TX (IEEE802.3)
Baud Rate
Automatically follows the master
Communication Cable Length
Depends on EtherCAT® Specification (Distance between each node:
100m or less)
Slave Type
I/O slave
Available Node Addresses for
Setting
0 to 127 (17 to 80 : When connected to the master (CJ1W-NC*82)
manufactured by OMRON)
Communications Cable
(Note1)
Category 5e or more
(Double shielded cable braided with aluminum foil recommended)
Connector
RJ45 Connector × 2pcs (Input×1, Output×1)
Connection
Daisy chain only
Note1: Please prepare a communication cable separately.
ME0306-2A
Summary of Contents for MSCON
Page 1: ...MSCON Controller Instruction Manual Second Edition ...
Page 2: ......
Page 4: ...ME0306 2A ...
Page 8: ...ME0306 2A ...
Page 20: ...12 ME0306 2A ...
Page 28: ...20 ME0306 2A ...
Page 46: ...Chapter 1 Specifications Check 38 ME0306 2A ...
Page 240: ...3 11 Gateway status LED 232 ME0306 2A ...
Page 246: ...Chapter 4 Vibration Suppress Control Function 238 ME0306 2A ...
Page 290: ...Chapter 7 Parameter 282 ME0306 2A ...
Page 310: ...Chapter 8 Troubleshooting 302 ME0306 2A ...
Page 354: ...Chapter 9 Appendix 346 ME0306 2A ...
Page 358: ......
Page 359: ......