3.4 Fieldbus
Type
Address Map
95
PLC Input (m is PLC input top word address for each axis number).
Address m
b15 b14 b13 b12 b11 b10
b9
b8
b7
b6
b5
b4
b3 b2 b1 b0
Current
Position
(Lower word)
Address m+1
b15 b14 b13 b12 b11 b10
b9
b8
b7
b6
b5
b4
b3 b2 b1 b0
Current
Position
(Upper word)
(Note)
If the target position is a negative value, it is indicated by a two’s complement.
Address m+2
b15 b14 b13 b12 b11 b10
b9
b8
b7
b6
b5 b4 b3 b2 b1 b0
Completed
Position No.
–
–
–
–
–
–
–
–
PM128
PM64
PM32
PM16
PM8
PM4
PM2
PM1
Address m+3
b15 b14 b13 b12 b11 b10
b9
b8
b7
b6
b5 b4 b3 b2 b1 b0
Status Signal
EMG
S
CRDY
ZONE
2
ZONE
1
PZO
N
E
–
–
MEND
BALM
–
PSFL
SV
ALM
MO
VE
HEND
P
E
N
D
1 word=16 bit