3.7
Control and functions of Input and output signals of Modes other than Remote I/O Mode
156
(11) Jog-speed/inch-distance switching (JVEL) PLC Output Signal
Operation
Mode
Positioner 1
Simple Direct
Direct numeric
specification
Direct numeric
specification 2
Positioner 2
Positioner 3
{
:
Equipped
×
:
Not equipped
{
{
{
×
{
×
It is a signal to switch the parameters to indicate the speed or inching (incremental) distance
when in JOG operation and inching operation.
Refer to [Relation between Settings and Operations for JVEL/JISL] below for the relation
between settings and operations.
(12) Jog/inching switching (JISL) PLC Output Signal
Operation
Mode
Positioner 1
Simple Direct
Direct numeric
specification
Direct numeric
specification 2
Positioner 2
Positioner 3
{
:
Equipped
×
:
Not equipped
{
{
{
×
{
×
This signal changes over the jog operation and the inching (incremental) operation.
JISL = OFF : Jog operation
JISL = ON : Inching operation
When the JISL signal is turned ON (for inching operation) during the jog operation, the actuator
is decelerated and performs the inching operation.
When the JISL signal is turned OFF (jog) while the actuator is moving by inching, the actuator
will complete the movement and then switch to the jog function.
Refer to [Relation between Settings and Operations for JVEL/JISL] below for the relation
between settings and operations.
[Relation between Settings and Operations for JVEL/JISL]
The relation of ON and OFF of Jog-speed/inch-distance switching (JVEL) and Jog/inching
switching (JISL) is as shown in the table below.
JISL
JISL = OFF (Jog operation)
JISL = ON (Inching operation)
Operation
When the JOG +/JOG – signal is ON. Upon detection of the leading (ON edge)
of the JOG +/JOG - signal.
JVEL
= OFF
Speed
Parameter No.26, “Jog speed”
Parameter No.26, “Jog speed”
Movement
distance
–
Parameter No.48, “Inch distance”
Acceleration/
deceleration
Rated value (The specific value varies
depending on the actuator.)
Rated value (The specific value varies
depending on the actuator.)
JVEL
= ON
Speed
Parameter No.47, “Jog speed 2”
Parameter No.47, “Jog speed 2”
Movement
distance
–
Parameter No.49, “Inch distance 2”
Acceleration/
deceleration
Rated value (The specific value varies
depending on the actuator.)
Rated value (The specific value varies
depending on the actuator.)
Note It is not available to have jog/inching operations in the setting of command speed for Direct
numeric specification mode/ Direct numeric specification mode 2.
ME0306-2A
Summary of Contents for MSCON
Page 1: ...MSCON Controller Instruction Manual Second Edition ...
Page 2: ......
Page 4: ...ME0306 2A ...
Page 8: ...ME0306 2A ...
Page 20: ...12 ME0306 2A ...
Page 28: ...20 ME0306 2A ...
Page 46: ...Chapter 1 Specifications Check 38 ME0306 2A ...
Page 240: ...3 11 Gateway status LED 232 ME0306 2A ...
Page 246: ...Chapter 4 Vibration Suppress Control Function 238 ME0306 2A ...
Page 290: ...Chapter 7 Parameter 282 ME0306 2A ...
Page 310: ...Chapter 8 Troubleshooting 302 ME0306 2A ...
Page 354: ...Chapter 9 Appendix 346 ME0306 2A ...
Page 358: ......
Page 359: ......