Chapter 7 Parameter
250
Parameter List (continued)
No.
Category
Name Symbol Unit
(Note 1)
Input Range
Default factory
setting
Relevant
sections
71 B Feed Forward Gain
PLFG
-
0 to 100
0
7.2 [41]
7.3
73 D Encoder Voltage Level
EVLV
-
0 to 3
Depending on
encoder cable
length
(Note 2)
7.2 [42]
75 D Electromagnetic Brake Power
Monitor
FSTP
-
0: Disabled
1: Enabled
In accordance
with actuator
(Note 2)
7.2 [43]
76 E Belt Breaking Sensor Input
Polarity
AIOF
For future
extension use.
Unavailable
77 D Ball Screw Lead Length
LEAD
mm
[deg]
0.01 to 999.99
In accordance
with actuator
(Note 2)
7.2 [45]
78 D Axis Operation Type
ATYP
-
0: Linear axis
1: Rotary axis
In accordance
with actuator
(Note 2)
7.2 [46]
79 B Rotary Axis Mode Selection
ATYP
-
0: Normal mode
1: Index mode
In accordance
with actuator
(Note 2)
7.2 [47]
80 B Rotational Axis Shortcut
Selection
ATYP
-
0: Disabled
1: Enabled
In accordance
with actuator
(Note 2)
7.2 [48]
88 D Software Limit Margin
SLMA
mm
0 to 9999.99
In accordance
with actuator
(Note 2)
7.2 [49]
89 D
Allowable time of exceeding
torque allowing continuous
pressing
PSCT
sec
0 to 300
In accordance
with actuator
(Note 2)
7.2 [50]
91 C
Current Limit Value at
Stopping Due to
Miss-pressing
FSTP
-
0: Current limit
during
movement
1: Current limit
value during
pressing
0
7.2 [51]
92 C Use of Loadcell Selection
FFRC
93 C Selection of Pressing Control
FFRC
94 C Pressing operation Using
Force Sensor Gain
FRCG
95 C Positive Side of Force
Judgment Margin
FJMM
96 C Negative Side of Force
Judgment Margin
FJML
For future
extension use.
Unavailable
97 C
Damping
Characteristic
Coefficient 1
DC11
-
0 to 1000
10
4.2
98 C
Damping
Characteristic
Coefficient 2
DC21
-
0 to 1000
1000
4.2
99 B
Natural Frequency
NP01
1/1000Hz
500 to 30000
10000
4.2
100 C
Vi
bration
suppre
ss
paramete
r s
et
1
Notch Filter Gain
NFG1
-
1 to 20000
9990
4.2
101 C
Damping
Characteristic
Coefficient 1
DC12
-
0 to 1000
10
4.2
102 C
Damping
Characteristic
Coefficient 2
DC22
-
0 to 1000
1000
4.2
103 B
Natural Frequency
NP02
1/1000Hz
500 to 30000
10000
4.2
104 C
Vi
bration
suppre
ss
paramete
r s
et
2
Notch Filter Gain
NFG2
-
1 to 20000
9990
4.2
Note 1: The unit [deg] is for rotary actuator.
It is displayed in mm in the teaching tools.
Note 2: The setting values vary in accordance with the specification of the actuator. At shipment, the
parameters are set in accordance with the specification.
ME0306-2A
Summary of Contents for MSCON
Page 1: ...MSCON Controller Instruction Manual Second Edition ...
Page 2: ......
Page 4: ...ME0306 2A ...
Page 8: ...ME0306 2A ...
Page 20: ...12 ME0306 2A ...
Page 28: ...20 ME0306 2A ...
Page 46: ...Chapter 1 Specifications Check 38 ME0306 2A ...
Page 240: ...3 11 Gateway status LED 232 ME0306 2A ...
Page 246: ...Chapter 4 Vibration Suppress Control Function 238 ME0306 2A ...
Page 290: ...Chapter 7 Parameter 282 ME0306 2A ...
Page 310: ...Chapter 8 Troubleshooting 302 ME0306 2A ...
Page 354: ...Chapter 9 Appendix 346 ME0306 2A ...
Page 358: ......
Page 359: ......