Chapter 7 Parameter
259
[16] Home return offset level (Parameter No.22)
No.
Name
Symbol
Unit
Input Range
Default factory
setting
22 Home Return Offset Level
OFST
mm
[deg]
0.00 to 9999.99
In accordance
with actuator
In this setting can set the distance from the encoder datum point (Z-phase) to the home
position.
An adjustment is available for the following cases.
1) Want to match the actuator home position and the mechanical origin of the system.
2) Want to set a new home after reversing the factory-set home direction.
3) Want to eliminate a slight deviation from the previous home position generated after
replacing the actuator.
[Adjustment Process]
1) Homing execution
2) Offset check
3) Parameter setting change
If setting a number close to a multiple of the lead length (including home-return offset value = 0)
to the home offset value, there is a possibility to servo lock on Z-phase at absolute reset, thus
the coordinates may get shifted for the lead length.
For Absolute Type, do not attempt to set a value near a number that the lead length is multiplied
by an integral number.
Have enough margin.
After the setting, repeat home return several times to confirm that the actuator always returns to
the same home position.
Caution: If the home return offset has been changed, the soft limit parameters must
also be adjusted accordingly.
In case the there is a necessity of setting a value more than the initial setting,
contact IAI.
[17] Zone 2 positive side, zone 2 negative side (Parameter No.23, No.24)
[Refer to 7.2 [1].]
ME0306-2A
Summary of Contents for MSCON
Page 1: ...MSCON Controller Instruction Manual Second Edition ...
Page 2: ......
Page 4: ...ME0306 2A ...
Page 8: ...ME0306 2A ...
Page 20: ...12 ME0306 2A ...
Page 28: ...20 ME0306 2A ...
Page 46: ...Chapter 1 Specifications Check 38 ME0306 2A ...
Page 240: ...3 11 Gateway status LED 232 ME0306 2A ...
Page 246: ...Chapter 4 Vibration Suppress Control Function 238 ME0306 2A ...
Page 290: ...Chapter 7 Parameter 282 ME0306 2A ...
Page 310: ...Chapter 8 Troubleshooting 302 ME0306 2A ...
Page 354: ...Chapter 9 Appendix 346 ME0306 2A ...
Page 358: ......
Page 359: ......