[46] Axis operation type (Parameter No.78)
No.
Name
Symbol
Unit
Input Range
Default factory
setting
78 Axis Operation Type
ATYP
-
0: Linear axis
1: Rotary axis
In accordance
with actuator
This parameter defines the type of the actuator used.
Connected Actuator Set Value
Reference
Linear Axis
0
Actuator other than rotational axis
Rotary Axis
1
Rotary Axis
(RS-30/60,
RCS2-RT6/RT6R/RT7/RT7R
/RTC8L/RTC8HL/RTC10L/RTC12L)
Caution: Do not change the setting of this parameter. Failure to follow this may cause
an alarm or fault to occur.