6.2.2 Replacement of absolute battery
For the battery replacement, remove the battery connector while keeping the power to the
controller ON, and change the battery installed in the battery holder.
Caution: To replace the old absolute battery with a new one with the controller
power being off, complete the replacement within 15 minutes from the
removal of the old battery if it is before the alarm is generated. The
absolute data may get lost if it exceeds 15 minutes.
[1] Absolute battery unit
Absolute battery unit consists of three components. [Refer to the diagram below]
Battery Cover
Battery (AB-5)
Battery Clip
y
Assembled Condition
[2]
Detachment
1) Unplug the connector for battery connection off the battery connector on the front panel of
controller.
2) Hold the point to detach the absolute battery unit and pull the absolute battery unit off
towards you.
[3] Attachment
1) Push the absolute battery unit along the attachment frame on the bottom of controller until
it makes a click noise.
2) Plug the connector for battery connection to the battery connector on the front panel of
controller. [Refer to 2.3.4 Battery Connection.]
Point to hold when
detaching the
absolute battery
unit from controller.
Connector for Battery Connection
Point to hold when separating the
absolute battery unit to battery cover
and battery clip.
ME0306-2A
Summary of Contents for MSCON
Page 1: ...MSCON Controller Instruction Manual Second Edition ...
Page 2: ......
Page 4: ...ME0306 2A ...
Page 8: ...ME0306 2A ...
Page 20: ...12 ME0306 2A ...
Page 28: ...20 ME0306 2A ...
Page 46: ...Chapter 1 Specifications Check 38 ME0306 2A ...
Page 240: ...3 11 Gateway status LED 232 ME0306 2A ...
Page 246: ...Chapter 4 Vibration Suppress Control Function 238 ME0306 2A ...
Page 290: ...Chapter 7 Parameter 282 ME0306 2A ...
Page 310: ...Chapter 8 Troubleshooting 302 ME0306 2A ...
Page 354: ...Chapter 9 Appendix 346 ME0306 2A ...
Page 358: ......
Page 359: ......