3.6 Power Supply and Cutoff
146
(3) Power supply status LED
The conditions of the control power and motor driving source can be checked on the power
supply status LEDs in the front panel.
{
: Illuminating, ×: OFF
Name
Status Display
Color
Description
{
Red
Turned ON when motor driving source is ON
(Keeps ON even if the driving source is turned OFF as long
as an electric charge is remained)
CHARGE
×
–
Motor driving source OFF
{
Green Control power source operating in normal condition
{
Orange
Control power source error (Turns ON when overvoltage is
applied or internal overcurrent is detected)
Condition remained until power shut down
PWR
×
–
Control power supply OFF
Warning (Electric Shock Caution)
Do not touch the terminals for motor power input connector and motor connector while
it is ON. You may get an electric shock in case the electric charge is still remained in
the capacitor even after the driving source is turned OFF.
ME0306-2A
Summary of Contents for MSCON
Page 1: ...MSCON Controller Instruction Manual Second Edition ...
Page 2: ......
Page 4: ...ME0306 2A ...
Page 8: ...ME0306 2A ...
Page 20: ...12 ME0306 2A ...
Page 28: ...20 ME0306 2A ...
Page 46: ...Chapter 1 Specifications Check 38 ME0306 2A ...
Page 240: ...3 11 Gateway status LED 232 ME0306 2A ...
Page 246: ...Chapter 4 Vibration Suppress Control Function 238 ME0306 2A ...
Page 290: ...Chapter 7 Parameter 282 ME0306 2A ...
Page 310: ...Chapter 8 Troubleshooting 302 ME0306 2A ...
Page 354: ...Chapter 9 Appendix 346 ME0306 2A ...
Page 358: ......
Page 359: ......