Chapter 2 Wiring
49
2.3.2 Wiring Layout of System I/O Connector
This consists of the emergency stop input and cable terminals for the operation mode
(AUTO/MANU) switch.
Strip the sheath of the applicable wires for 10mm and insert them to the connector. Push a
protrusion beside the cable inlet with a small slotted screwdriver to open the inlet. Once the
cable is inserted, take the slotted screwdriver off the protrusion to fix the cable to the terminal.
System I/O
Connector
Model Remarks
Cable Side
FMCD1.5/4-ST-3.5
Enclosed in standard
package
Manufactured by PHOENIX
CONTACT
Controller Side MCDN1.5/4-G1-3.5P26THR
Pin
No.
Signal
Name
Contents
Applicable
Cable
1 EMG+
+24V power output for emergency stop
2 S2
For external emergency stop signal input
3 S1
For external emergency stop signal output
4 EMG-
Emergency-stop input
5 A/M+
+24V output for operation mode
(AUTO/MANU) switchover
6 A/M-
Operation mode (AUTO/MANU)
switchover signal input
KIV1.25 to
0.2mm
(AWG16 to
24)
7 NC
8 NC
Connection is not required
Accessory
Connector
(Plug)
Emergency Stop
Circuit
Front view of
connector on
controller side
A/M-
A/M+
EMG-
S1
S2
EMG+
ME0306-2A
Summary of Contents for MSCON
Page 1: ...MSCON Controller Instruction Manual Second Edition ...
Page 2: ......
Page 4: ...ME0306 2A ...
Page 8: ...ME0306 2A ...
Page 20: ...12 ME0306 2A ...
Page 28: ...20 ME0306 2A ...
Page 46: ...Chapter 1 Specifications Check 38 ME0306 2A ...
Page 240: ...3 11 Gateway status LED 232 ME0306 2A ...
Page 246: ...Chapter 4 Vibration Suppress Control Function 238 ME0306 2A ...
Page 290: ...Chapter 7 Parameter 282 ME0306 2A ...
Page 310: ...Chapter 8 Troubleshooting 302 ME0306 2A ...
Page 354: ...Chapter 9 Appendix 346 ME0306 2A ...
Page 358: ......
Page 359: ......