7-93
DISASSEMBLY
Clean pilot valve with kerosene.
Put blind plugs into all ports
Fix pilot valve in a vise with copper(or
lead) sheets.
Remove end of boot(32) from case(1)
and take it out upwards.
(1)
ö
(2)
(3)
Loosen lock nut(24) and adjusting nut(22)
with spanners on them respectively, and
take out handle section as one body.
(4)
For valve with switch, remove cord also
through hole of casing.
ö
3)
Remove the boot(32).
(5)
1408DA62
1408DA63
1408DA64