5-35
12. WHEN STARTING SWITCH IS TURNED ON, WORK LAMP DOES NOT LIGHTS UP
Â
Before disconnecting the connector, always turn the starting switch OFF.
Â
Before carrying out below procedure, check all the related connectors are properly inserted and
short of fuse No.5.
Â
After checking, insert the disconnected connectors again immediately unless otherwise specified.
Cause
Remedy
Defective lamp
switch
Defective bulb
Disconnection in
wiring harness or
poor contact
between CN3(14)
and CL-5(2)
Disconnection in
wiring harness or
poor contact
between
CS-21(2)-CN-
3(14)
Disconnection in
wiring harness or
poor contact
between CS-21
(4) and fuse
Replace switch
Replace
Repair or replace
(After clean)
Repair or replace
(After clean)
Repair or replace
(After clean)
Check voltage
between CS-21
(4) and chassis
YES
NO
Starting switch : ON
Work lamp switch :
ON-OFF
Voltage : 10~12.5V
Starting switch : ON
Work lamp switch : ON
Voltage : 10~12.5V
Starting switch : ON
Work lamp switch : ON
Voltage : 10~12.5V
Starting switch : ON
Work lamp switch : ON
Voltage : 10~12.5V
Check voltage
between CL-5(2)
and chassis
Check voltage
between CN-3
(14) and chassis
Check voltage
between CS-21
(4) and (2)
NO
YES
YES
YES
NO
NO
CL-5
1
2
CN-3
CS-21
LIGHT SW
5
1
9
10
1
2
3
4
5
6
7
8
9
10
2
4
7
0
I
FUSE
NO.5
13
CN-7
3
CN-2
8
CN-12
2
WORK LAMP
14
R35Z75TS21