2-69
The force of the spring(8) that determines the output pressure of the pilot valve is not applied to
the spool(11). Therefore, the spool is pushed up by the spring(4) to the position of port(1, 3) in the
operation explanation drawing. Then, since the output port is connected to tank port T only, the
output port pressure becomes equal to tank pressure.
Case where handle is in neutral position
8
11
3
T
1
4
P
(1)
R35Z72RL03