6-29
5. TURNING JOINT
Maintenance standards
Remedy
Plating worn or peeled due to seizure or contamination.
Â
Worn abnormality or damaged more than 0.1mm
(0.0039in) in depth due to seizure contamination.
Â
Damaged more than 0.1mm(0.0039in) in depth.
Â
Worn more than 0.5mm(0.02in) or abnormality.
Â
Worn less than 0.5mm(0.02in).
Â
Damage due to seizure or contamination remediable
within wear limit (0.5mm)(0.02in).
Â
Worn more than 0.5mm(0.02in) or abnormality.
Â
Worn less than 0.5mm(0.02in).
Â
Damage due to seizure or contamination remediable
within wear limit (0.5mm)(0.02in).
Â
Extruded excessively from seal groove square ring.
Â
Slipper ring 1.5mm(0.059in) narrower than seal
groove, or narrower than back ring.
Â
Worn more than 0.5mm(0.02in) ~ 1.5mm(MAX.)
(0.059in)
Sliding surface with
sealing sections.
Sliding surface
between body and
stem other than
sealing section.
Sliding surface
with thrust plate.
Sliding surface
with thrust plate.
-
-
-
Replace
Replace
Smooth with oilstone.
Replace
Smooth
Smooth
Replace
Smooth
Replace
Replace
Replace
Replace
Part name
Body,
Stem
Cover
Seal set
Square ring
Extrusion
1.5mm (max.)
(0.059in)