5-25
2. BATTERY CHARGING WARNING LAMP LIGHTS UP(Starting switch : ON)
Â
Before disconnecting the connector, always turn the starting switch OFF.
Â
Before carrying out below procedure, check all the related connectors are properly inserted.
Â
After checking, insert the disconnected connectors again immediately unless otherwise specified.
Cause
Remedy
Defective cluster
Disconnection in
wiring harness or
poor contact
between CN-56(3)
-CN2(13)
Disconnection in
wiring harness or
poor contact
between
CN-2(13)-alternator
terminal "1"
Defective alternator
Replace
Repair or replace
(After clean)
Repair or replace
(After clean)
Replace
YES
YES
YES
NO
NO
NO
CLUSTER
CN-56
10 ~ 12.5V
YES
Check voltage
NO
0V
3
CN-2
13
ALTERNATOR
CN-74
3
2
1
U
3
~
G
L
P
I
B+
Voltage : 10~12.5V
Engine : Running
Check voltage
between alternator
terminal "1" and
chassis
Check voltage
between CN-2
(13) and chassis
Check voltage
between CN-56
(3) and chassis
R35Z75TS11