HydraSwing Programming & Operations
© 2018
Installer Menu
Setting Options
Menu Tasks & Explanations
STC Wire
Connections
TL 2 (45 SECS)
OPEN TIME ALERT
2 = 45 second delay
0 = 0s delay
1 = 15s
3 = 75s
4 = 105s
5 = 135s
OPEN TIME ALERT lets you specify when
the #8 User Relay activates. The relay turns
ON when the software detects that the gate
operator has been off its close limit for the
specified period of time.
NOTE:
In previous versions of software,
this menu item only appeared when the #8
User Relay function (Rx 8 OPEN2LONG)
was configured. Now, even without the
User Relay option 8 being utilized, TL is a
standard Installer Menu item.
User Relay 8
LT 3 (75 SECS)
LOITERING ALERT
3 = 75 second delay
0 = 0s delay
1 = 15s
2 = 45s
4 = 105s
5 = 135s
The LOITERING alert lets you specify
when the #13 User Relay activates. When
connected and configured, it indicates
a vehicle is loitering on the Outside
Obstruction Loop. The alert time is
adjustable from 0 seconds, with 15 to
135s selectable delay timeframes in 30s
increments.
NOTE:
LT LOITERING alert adjustments
can be made in the Installer Menu. In
previous versions of software, this menu
item only appeared when the #13 User
Relay function (Rx 13 LOITERING) was
configured. Now, even without the User
Relay option 13 being utilized, LT is a
standard Installer Menu item.
User Relay 13
OS 1 (30 SEC)
OPEN SPEED
0 = Run mode
1 = (30 SEC)
2 = (25 SEC)
3 = (20 SEC)
Designate how quickly the gate opens. The
range is dependent on the model number
the speed varies. Refer to
(N/A)
CS 1 (30 SEC)
CLOSE SPEED
0 = Run mode
1 = (30 SEC)
2 = (25 SEC)
3 = (20 SEC)
Designate how quickly the gate closes. The
range is dependent on the model number
the speed varies. Refer to
(N/A)
LL 0 (OFF)
Learn Limit Reset
0 = Normal setting
1 = Erases the learned limit positions
Set to option 1, the system resets to
accommodate for relearning limits. Refer to
N/A
SA 0 (OFF)
STC ADDRESS
0 = No network
1 to 99 = Network “drop” address
Sets the system address for network
communication. 1 – 99 sets individual poling
addresses.
Refer to
for more
information.
RS-485. Involves
additional
hardware &
software.
NE 0 (OFF)
NETWORK SETUP
0 = No network (off)
1 = Network address (on)
Menu item appears when SA is not set to
zero (0).
If a system address exists a setting of 1
opens the network configuration menu.
0 = no network communication
1 = allows configuration of network
addresses. Used with HyNet
™
.
RS-485. Involves
HyNet
™
&
software.
Summary of Contents for HSG80F
Page 2: ...www SecureOpeners com 800 878 7829 Sales SecureOpeners com...
Page 14: ...Page intentionally left blank xiv MX3636 01 Rev D HydraSwing Programming Operations 2018...
Page 36: ...Page intentionally left blank 22 MX3636 01 Rev D HydraSwing Programming Operations 2018...
Page 124: ...110 MX3636 01 Rev D HydraSwing Programming Operations 2018 Page intentionally left blank...
Page 136: ...122 MX3636 01 Rev D HydraSwing Programming Operations 2018...