Display & Menu Options
MX3636-01 Rev. D
51
Installer Menu
Setting Options
Menu Tasks & Explanations
STC Wire
Connections
HD 1 HOLD CLOSE
Center Loop Hold
0 = Hold Open only
1 = Hold Close and hold Open
Swing gates:
Configures the function of the
Center Loop (Shadow Loop) when triggered:
Setting 1 - holds the gate from starting open
and from starting close. This setting prevents
opening and closing of the gate when the
Center Loop is tripped if the gate is on
either (opened or closed) limit switches.
Setting 0 - holds the gate from starting
closed. This setting prevents closing when
on the open limit switch.
CENTER LOOP
(#10)
COM or
connection to
Hy5B detector
DL 1 STANDARD
DETECTOR LOGIC
1 = Standard
2 & 3 = Quick Close
4 = Full anti-tailgate
Determines how the operator responds to a
tail gate notification. See
NOTE:
Does not appear in barrier gate
operators.
RL 1 CLOSE LIM
RELAY 1 LOGIC
0 = Disabled
1 = Close limit active
(1 to 29 available)
Configures the function of the User 1 output
relay. It has the capacity to switch both AC
and DC loads and can be used for high
voltage and/or high current loads. Connect
devices directly to the top of the relay: COM
and either NO and/or NC contacts. Multiple
logic function options exist. Refer to
Relays – Programming Procedure
User 1 Relay
R2 6 GATE LOCK
RELAY 2 LOGIC
0 = Disabled
1 to 29 available
Configures the function of the User 2 output
relay. It has the capacity to switch both AC
and DC loads and can be used for high
voltage and/or high current loads. Connect
devices directly to the top of the relay: COM
plus NO and NC contacts. Multiple optional
logic function options exist. Refer to
Relays – Programming Procedure
User 2 Relay
R3 1 CLOSE LIM
RELAY 3 LOGIC
0 = Disabled
1 to 29 available
Relay 3 configures the function of the User
3 output relay, which is an electronic relay
with the capacity for switching a DC load
only. In the StrongArm M30/M50, Relay 3
is connected to the gate LED lighting and
does not appear as an option in the Installer
Menu.
User 3 Relay
R4 through R11
RELAY <n> LOGIC
0 = Disabled
1 to 29 available
Similar to Relay 1 Logic.
NOTE:
The Hy8Relay
™
module option can
be purchased to provide an additional
8 relay terminals. Relay #39 set aside for
Factory Use.
COM
NOTE:
R4
through RB user
relays appear
on 7-segment
display
Summary of Contents for HSG80F
Page 2: ...www SecureOpeners com 800 878 7829 Sales SecureOpeners com...
Page 14: ...Page intentionally left blank xiv MX3636 01 Rev D HydraSwing Programming Operations 2018...
Page 36: ...Page intentionally left blank 22 MX3636 01 Rev D HydraSwing Programming Operations 2018...
Page 124: ...110 MX3636 01 Rev D HydraSwing Programming Operations 2018 Page intentionally left blank...
Page 136: ...122 MX3636 01 Rev D HydraSwing Programming Operations 2018...