w
irinG
t
ipS
fOr
SenSOr cOm t
erminaL
: S
mart
t
OucH
Two SENSOR COM terminals exist (Terminal 14 and Terminal 15). If using multiple sensor devices, use a wire nut as a
junction and pigtail to SENSOR COM. Or, install a separate terminal block and jumper outputs to one lead for either
SENSOR COM terminal.
CAUTION
All external entrapment protection sensors must be NC sensor outputs and wired to the SENSOR COM terminal
for monitoring and powering purposes. The sensor becomes actively powered when the gate operator receives a
run command.
NOTE:
LEDs next to the sensor connections will be lit when NO POWER is being applied. To temporarily supply power to the
sensors. Refer to
on page 88. When PE is turned ON, the LEDs turn off. If they do not turn off, check
for wiring issues such as a short or misapplied relay COM connections. Refer to
on page 34.
m
enu
m
Ode
n
aViGatiOnaL
t
ipS
Press the Menu button twice to access Menu mode. The gate will not run while in Menu mode. The buttons on the display
keypad perform certain functions while in Menu Mode. Refer to the chart.
To change data
appearing in the display
To navigate through
the Selections
To choose what appears
on the display
To navigate between
menu items
Press
Select
.
Two left characters blink.
Press
Next
or
Previous
.
Continue pressing Next to
view all selections.
Press
Select
.
Blinking characters
become static.
Press
Next
or
Previous
.
Advance - press Next
Previous - press Previous
SHADOW/RESET
VEHICLE DETECTOR
SENSOR 1
SENSOR COM
DO NOT USE
SENSOR 2
DO NOT USE
SENSOR 3
DO NOT USE
CHARGER
AC LOSS
LOCK INTERLOCK
EMERG CLOSE
FIRE DEPT OPEN
12
14
15
16
17
18
19
20
21
22
23
24
Smart Touch Controller
LIMIT
DUAL GATE
COM
COM
A
B
RPM
LED
Wires coming from
sensor device
Wire nut and pigtail to SENSOR COM
Add terminal block
Wires coming
from sensor
device
Wire to
SENSOR
COM
Connect
sensor's "Relay
COM"wiring
to Terminal 14
or 15
(SENSOR COM)
112
MX3636-01 Rev. D
HydraSwing Programming & Operations
© 2018
Summary of Contents for HSG80F
Page 2: ...www SecureOpeners com 800 878 7829 Sales SecureOpeners com...
Page 14: ...Page intentionally left blank xiv MX3636 01 Rev D HydraSwing Programming Operations 2018...
Page 36: ...Page intentionally left blank 22 MX3636 01 Rev D HydraSwing Programming Operations 2018...
Page 124: ...110 MX3636 01 Rev D HydraSwing Programming Operations 2018 Page intentionally left blank...
Page 136: ...122 MX3636 01 Rev D HydraSwing Programming Operations 2018...