The Smart Touch Controller is able to interface with many types
of external devices through the use of three user programmable
output relays: two mechanical relays (User Relay 1 and User
Relay 2), and one solid state relay (User 3) which is used most often
for connection to flashing devices.
All of the user relay functions identified and described in the table
below are accessible in the Installer Menu
(R1 x, R2 x, R3 x) selections.
NOTE:
A setting of zero disables a User Relay. The User Relays will operate
normally to 18VDC. Below 18VDC, alert notification occurs. On Crash products
User 3 relay is unavailable. It is pre-wired for the LED lights.
Use the STC buttons to program the user relays according to
the following steps:
1. Select the relay you wish to use through the Installer
Menu. See
example:
R1 13
(RELAY LOGIC 1) or R2 15 (RELAY LOGIC 2).
2. Select the appropriate function (1 through 28) by
changing the display to the associated number listed in
the table. Use the Select, Next and Previous buttons to
Table 7: Programmable User Relays
Setting
Performance
Description
Wire
Connection
1
Close limit output
Output can be used as an interlock signal to another
operator’s interlock input, or simply to indicate that the gate
is secure. The relay is “off” when the gate is closed. The relay
energizes when the fully-closed limit is released. (Any open
command energizes the relay.)
Relay 1, 2 or 3
2
Close limit pulse output
Used in a sequenced system to command a second machine
to close. Generates a brief pulsed output that occurs when
the close limit is triggered.
Relay 1, 2 or 3
3
Open limit output
Indicates a full-open position. This output becomes active
when an open-limit is triggered and deactivates when the
open-limit is released or a close command is received.
Relay 1, 2 or 3
4
Open limit pulse output
Used in a sequenced gate system to command a second
machine to open. Generates a brief pulsed output that
occurs when the open limit is triggered.
Relay 1, 2 or 3
5
Warn before/during operate output
Controls an external warning device. This output operates at
the same time as the internal warn before operate buzzer.
Relay 1, 2 or 3
6
Gate Lock output
Controls external solenoid or magnetic locks. In both
directions of travel, this output is activated about 7/10ths of
a second before the operator starts moving the gate and
remains active while moving. Output remains active, for a
few seconds, after stopping.
Relay 1, 2 or 3
STC display (7-segment)
Identifies relay number
Setting
R1 1 CLOSE LIM
RELAY 1 LOGIC
STC display (32 character OLED)
Performance
Setting
Identifies relay
number
Description
Summary of Contents for HSG80F
Page 2: ...www SecureOpeners com 800 878 7829 Sales SecureOpeners com...
Page 14: ...Page intentionally left blank xiv MX3636 01 Rev D HydraSwing Programming Operations 2018...
Page 36: ...Page intentionally left blank 22 MX3636 01 Rev D HydraSwing Programming Operations 2018...
Page 124: ...110 MX3636 01 Rev D HydraSwing Programming Operations 2018 Page intentionally left blank...
Page 136: ...122 MX3636 01 Rev D HydraSwing Programming Operations 2018...