56
MX3636-01 Rev. D
HydraSwing Programming & Operations
© 2018
t
eSt
tHe
O
peratOr
Complete the installation by testing the operation of the gate.
NOTE:
The operator must be turned on and in Run mode. A Run mode display appears on the STC. If a Run mode status does not
appear on the display, press Reset. If an error, alert, or fault appears on the display, refer to the
how to clear the display and return to Run mode.
1. Press Open to open the gate.
2. Test the operator.
• Cycle the gate a few times by pressing the Close and Open buttons.
• If installed for emergency fast operation, test the EMERGENCY CLOSE using the constant hold
device. Observe the travel speed of the gate when you press and hold the Emergency Close
button. It will close a second or two faster than normal operation and ignore any photo eye, vehicle
loop, or other safety sensor inputs.
NOTE:
If additional accessories are to be added, read about
HydraSupply Cabinet
(Hydraulic pump pack, motor
& Smart Touch Controller)
Gate edge
sensors
Warning signs
(placed on both sides of gate
Pedestrian
gate
Access
controls
Shadow loop
(Center Loop)
HydraSwing
HydraSwing
Summary of Contents for HSG80F
Page 2: ...www SecureOpeners com 800 878 7829 Sales SecureOpeners com...
Page 14: ...Page intentionally left blank xiv MX3636 01 Rev D HydraSwing Programming Operations 2018...
Page 36: ...Page intentionally left blank 22 MX3636 01 Rev D HydraSwing Programming Operations 2018...
Page 124: ...110 MX3636 01 Rev D HydraSwing Programming Operations 2018 Page intentionally left blank...
Page 136: ...122 MX3636 01 Rev D HydraSwing Programming Operations 2018...