90
MX3636-01 Rev. D
HydraSwing Programming & Operations
© 2018
Compatibility
The UL 325 Standard of Safety requires that a photoelectric sensor be laboratory tested and “recognized”
under UL 325. In order to be compatible with all HySecurity gate operators, a photo eye must be rated to
function from 24 VDC source power.
A list of tested and approved external entrapment protection sensors (normally closed contacts) that are
compatible with HySecurity gate operators can be found online at the following public site:
.
Installation
NOTE:
Follow the manufacturer’s installation and assembly instructions to properly mount the sensor. Wiring diagrams for several
sensor devices are found in
Wiring HySecurity Sensors: Smart Touch on page
111.
HySecurity gates monitor normally closed (NC) sensors. Wire the NC sensors to SENSOR input terminals
(SENSOR 1, SENSOR 2, or SENSOR 3) on the Smart Touch Controller and set the Installer Menu item S1, S2,
or S3 to the appropriate setting for the area being monitored.
When using wired edge sensors, the wired edge must be connected to an interface module with an NC
output. Miller Edge
®
has marked UL 325 - 2016 compliant edge sensors with blue electrical tape on the output
wire. These edge sensors have a 10k
Ω
resistor that connects to an interface module. The interface module
provides the NC output for monitoring purposes. Refer to
Wiring HySecurity Sensors: Smart Touch
on
page 111.
For wireless edge sensors, no interface module is required. Wireless edge sensors need the wireless gate links
which include a transmitter and receiver. HySecurity has created kits for all-inclusive shipment.
NOTE:
The installation locations are intended for pedestrian detection and safety. The potential zones requiring entrapment
protection are areas that need to be protected for pedestrian safety.
Gate Edge Function
If the gate is stationary, a tripped gate edge sensor will prevent the gate from starting in either direction.
If tripped while in motion, the standard function is to stop the gate movement and, if tripped while closing,
automatically re-open fully. An optional setting in the Installer Menu will cause a 2 second reversal if triggered
for more information.
Example: Wired gate edges used with 10K
Ω
(8.2K
Ω
) resistor
Example: Wireless gate link (transmitter &
receiver) used with wireless gate edges
Summary of Contents for HSG80F
Page 2: ...www SecureOpeners com 800 878 7829 Sales SecureOpeners com...
Page 14: ...Page intentionally left blank xiv MX3636 01 Rev D HydraSwing Programming Operations 2018...
Page 36: ...Page intentionally left blank 22 MX3636 01 Rev D HydraSwing Programming Operations 2018...
Page 124: ...110 MX3636 01 Rev D HydraSwing Programming Operations 2018 Page intentionally left blank...
Page 136: ...122 MX3636 01 Rev D HydraSwing Programming Operations 2018...