© 2018
Installing Gate Edge Sensors
MX3636-01 Rev. D
89
Installing Gate Edge Sensors
A monitored connection tests for the presence and correct operation of the gate edge sensors (and other
monitored sensors) prior to gate activation. The monitored connection prevents gate operation if a sensor is
missing or any fault is present.
Sensors, such as gate edges and photoelectric beams, must be installed to protect against entrapment. These
external entrapment protection sensors are required for the gate installation to be in compliance with the
2016, UL 325 Standard of Safety (6th Edition).
NOTICE:
UL 325 Standard of Safety provides the MINIMUM safety standards. Site, gate hardware usage,
and other conditions may dictate the use of additional safety designs/components. It is up to the gate system
designer and installer to assess appropriate safety design and components above and beyond minimum UL 325
and ASTM F2200 Standard of Safety. Always check your local area codes and comply with all regulations.
Assess your gate site for the most appropriate placement of edge sensors. Plan to integrate contact (gate
edge) and non-contact (photo eyes) sensors in your site plan. Sensors are wired to the Controller and require
low voltage conduit to the operator and power supply. Refer to
External Entrapment Protection Sensors
monitored by HySecurity Gate Operators
on page iii.
To enable fully automatic operation, this gate operator requires a MINIMUM of one external entrapment
protection sensor to monitor potential entrapment zones in either the open or close direction of travel.
WARNING
Mo
ving Ga
te Can
Cause
Ser
ious
Injur
y or Dea
th
KEEP CLE
AR! G
ate
ma
y mo
ve a
t an
y �me
with
out
prior w
arn
ing.
Do n
ot le
t chi
ldren op
era
te th
e ga
te or
play i
n
the
gat
e ar
ea.
This e
ntran
ce is f
or v
ehicles onl
y. A
ll pe
des
trians
mus
t use
a separ
ate
entr
ance
.
Read
the
owner
’s manu
al an
d sa
fety in
struc�ons.
Swing Gates:
Potential Zones requiring
Entrapment Protection
1. Leading Edge
2. Bottom Edge
3. Entry / Exit
4. Posts
5. Post Pivot / Pinch Points
6. Arm Movement
Secure side
Public side
Drawing NOT TO SCALE
1
3
2
4
5
6
3
NOTE:
SwingRiser shown for reference.
HydraSwing zones are similar.
Summary of Contents for HSG80F
Page 2: ...www SecureOpeners com 800 878 7829 Sales SecureOpeners com...
Page 14: ...Page intentionally left blank xiv MX3636 01 Rev D HydraSwing Programming Operations 2018...
Page 36: ...Page intentionally left blank 22 MX3636 01 Rev D HydraSwing Programming Operations 2018...
Page 124: ...110 MX3636 01 Rev D HydraSwing Programming Operations 2018 Page intentionally left blank...
Page 136: ...122 MX3636 01 Rev D HydraSwing Programming Operations 2018...