background image

Leading the way ...

Installation Manual

820/860

Leading the way ...

Sliding Gate System

Leading the way ...

Summary of Contents for 820

Page 1: ...Leading the way Installation Manual 820 860 Leading the way Sliding Gate System Leading the way...

Page 2: ...nt amendments 91 368 EEC 93 44 EEC and 93 68 EEC complieswiththeessentialsafetyrequirementsinthefollowingEECDirectives 73 23 EEC and subsequent amendment 93 68 EEC 89 336 EEC and subsequent amendments...

Page 3: ...provided for the installation with an opening distance of the contacts of 3 mm or more Alternatively use a 6A thermomagnetic breaker with multi pole switching 13 Ensure that there is a differential s...

Page 4: ...tial opening length 1 60 m 1 20 m Cooling self ventilated Clutch single disc in oil bath Housing treatment cataphoresis Casing painting polyester RAL 7042 Control unit 826 MPS incorporated Limit switc...

Page 5: ...ndation plinth as shown in Fig 8 and install the base plate providing one or more conduits for electrical cables Use a level to check that the plate is perfectly horizontal and wait for the cement to...

Page 6: ...ate Drill a 6 5 mm diameter hole and thread using 8 mm screw taps Tighten the bolt 4 Slide the gate manually making sure that the rack rests on the pinion and repeat the operations of point 3 5 Place...

Page 7: ...6 5 4 3 1 4 5 2 MODEL 820 EMC RF 860 MC RF figs 20 21 Insert the elastic pin 7 in the shaft with the aid of a hammer Fit the chain pinion on the shaft by matching up the pinion seats with the elastic...

Page 8: ...the 230 Vac terminals to which the flashing light must be connected 5 2 8 230 V MAINS SUPPLY terminals 13 14 These are the terminals to which the 230 Vac electricity supply must be connected Connect t...

Page 9: ...recloses 2 STOP no effect stops counting stops stops no effect SAFETY no effect recloses after 5 s stops and inverts motion when disengaged 2 no effect no effect TABLE 8 LOGIC A2 AUTOMATIC LOGIC S1 I...

Page 10: ...be positioned to ON for closure to left and OFF for closure to right The positions of dipswitches SW4 SW5 and SW6 have no effect 3 Move the gate manually to its mid travel position 4 Switch on the ele...

Page 11: ...by losing the centre scale position of the ADL the following steps must be carried out to restore the start condition 1 Release the operator 2 Slide the gate manually to the mid travel position 3 Remo...

Page 12: ...11 Fig 29 Fig 30 1 2 A B Fig 32 Fig 31 OIL...

Page 13: ...n has been selected a second impulse must be sent to reclose the gate An opening impulse send while the gate is reclosing causes it to change direction of movement A stop command if available stops mo...

Page 14: ...for either technical or commercial reasons at any time and without revising the present publication FAAC UK Limited 6 Hamilton Close Houndmills Estate Basingstoke RG21 6YT Telephone 01256 318100 Fax 0...

Reviews: