background image

6

Fig. 15

Fig. 16

N.B.:

 Check that none of the rack elements come off the

pinion during the movement of the gate.

Important:

 Do not weld the rack elements either to the

spacers or to each other (for steel rack only).
After installing the rack, lower the position of the gear motor
by adjusting the feet (Fig. 17) by about 1.5 mm to ensure
correct meshing with the pinion.

1.5

Fig. 17

5. START-UP

5.1.

CONNECTION TO ELECTRONIC CONTROL UNIT

Warning: Always turn off the electricity supply before
carrying out any work on the electronic control unit
(connections, programming, maintenance).
Warning: When terminal board J2 is disconnected, high
voltage remains on the outputs of the capacitor, motor and
transformer power supplies.

Observe points 10, 11, 12, 13 and 14 in the GENERAL SAFETY
INSTRUCTIONS.
As shown in Fig. 2, prepare the conduits and make the
electrical connections from the 826 MPS electronic control
unit to the chosen accessories.

7

2

1

6

5

4

3 1

4.5.2

MODEL 820 EMC RF - 860 MC RF (figs. 20-21)

- Insert the elastic pin 7 in the shaft with the aid of a

hammer.

- Fit the chain pinion on the shaft by matching up the

pinion seats with the elastic pin and tighten up screw 4
and washers 5 and 6.

- Fit the idle transmission bracket on the gear motor flange,

removing the four upper bolts and replacing them with
the 5x12 hex bolts 1 and washers 2 in the kit as shown in
Fig. 20.

- Fit the chain as shown in Fig. 21 and mount the casing with

screws 1 and washers 3 (Fig. 20).

Fig. 20

Fig. 21

Check manually that the gate reaches the mechanical
travel limits correctly and that it does not encounter
friction during its travel.
Do not use grease or other lubricants between the pinion
and the rack.

4.5.

MOUNTING CHAIN PINIONS

In versions for chain and idle transmission applications,
mount the Z16 or Z20 chain pinion. Proceed as follows:

4.5.1

MODEL 820 EMC - 860 MC - 860 EMC (figs. 18-19)

- Insert the elastic pin in the shaft with the aid of a hammer.

- Fit the chain pinion on the shaft by matching up the pinion

seats with the elastic pin and tighten up the screw with the
washers.

Fig. 18

Fig. 19

Summary of Contents for 820

Page 1: ...Leading the way Installation Manual 820 860 Leading the way Sliding Gate System Leading the way...

Page 2: ...nt amendments 91 368 EEC 93 44 EEC and 93 68 EEC complieswiththeessentialsafetyrequirementsinthefollowingEECDirectives 73 23 EEC and subsequent amendment 93 68 EEC 89 336 EEC and subsequent amendments...

Page 3: ...provided for the installation with an opening distance of the contacts of 3 mm or more Alternatively use a 6A thermomagnetic breaker with multi pole switching 13 Ensure that there is a differential s...

Page 4: ...tial opening length 1 60 m 1 20 m Cooling self ventilated Clutch single disc in oil bath Housing treatment cataphoresis Casing painting polyester RAL 7042 Control unit 826 MPS incorporated Limit switc...

Page 5: ...ndation plinth as shown in Fig 8 and install the base plate providing one or more conduits for electrical cables Use a level to check that the plate is perfectly horizontal and wait for the cement to...

Page 6: ...ate Drill a 6 5 mm diameter hole and thread using 8 mm screw taps Tighten the bolt 4 Slide the gate manually making sure that the rack rests on the pinion and repeat the operations of point 3 5 Place...

Page 7: ...6 5 4 3 1 4 5 2 MODEL 820 EMC RF 860 MC RF figs 20 21 Insert the elastic pin 7 in the shaft with the aid of a hammer Fit the chain pinion on the shaft by matching up the pinion seats with the elastic...

Page 8: ...the 230 Vac terminals to which the flashing light must be connected 5 2 8 230 V MAINS SUPPLY terminals 13 14 These are the terminals to which the 230 Vac electricity supply must be connected Connect t...

Page 9: ...recloses 2 STOP no effect stops counting stops stops no effect SAFETY no effect recloses after 5 s stops and inverts motion when disengaged 2 no effect no effect TABLE 8 LOGIC A2 AUTOMATIC LOGIC S1 I...

Page 10: ...be positioned to ON for closure to left and OFF for closure to right The positions of dipswitches SW4 SW5 and SW6 have no effect 3 Move the gate manually to its mid travel position 4 Switch on the ele...

Page 11: ...by losing the centre scale position of the ADL the following steps must be carried out to restore the start condition 1 Release the operator 2 Slide the gate manually to the mid travel position 3 Remo...

Page 12: ...11 Fig 29 Fig 30 1 2 A B Fig 32 Fig 31 OIL...

Page 13: ...n has been selected a second impulse must be sent to reclose the gate An opening impulse send while the gate is reclosing causes it to change direction of movement A stop command if available stops mo...

Page 14: ...for either technical or commercial reasons at any time and without revising the present publication FAAC UK Limited 6 Hamilton Close Houndmills Estate Basingstoke RG21 6YT Telephone 01256 318100 Fax 0...

Reviews: