background image

FAAC (UK) Limited, 6 Hamilton Close
Houndmills Estate, Basingstoke, RG21 6YT
Telephone: 01256 318100
Fax: 01256 318101
Email: [email protected]
Website: www.faac.co.uk

V5 01/07

Your authorised FAAC dealer

The descriptions and illustrations contained in this manual are not     
binding. FAAC reserve the right, whilst leaving the main features of 
the main equipment unaltered, to undertake any modi

fi

 cations it holds      

necessary for either technical or commercial reasons, at any time and 
without revising the present publication.

FAAC (UK) Limited, 6 Hamilton Close
Houndmills Estate, Basingstoke, RG21 6YT
Telephone: 01256 318100
Fax: 01256 318101
Email: [email protected]
Website: www.faac.co.uk

V5 01/07

Your authorised FAAC dealer

The descriptions and illustrations contained in this manual are not     
binding. FAAC reserve the right, whilst leaving the main features of 
the main equipment unaltered, to undertake any modi

fi

 cations it holds      

necessary for either technical or commercial reasons, at any time and 
without revising the present publication.

Summary of Contents for 820

Page 1: ...Leading the way Installation Manual 820 860 Leading the way Sliding Gate System Leading the way...

Page 2: ...nt amendments 91 368 EEC 93 44 EEC and 93 68 EEC complieswiththeessentialsafetyrequirementsinthefollowingEECDirectives 73 23 EEC and subsequent amendment 93 68 EEC 89 336 EEC and subsequent amendments...

Page 3: ...provided for the installation with an opening distance of the contacts of 3 mm or more Alternatively use a 6A thermomagnetic breaker with multi pole switching 13 Ensure that there is a differential s...

Page 4: ...tial opening length 1 60 m 1 20 m Cooling self ventilated Clutch single disc in oil bath Housing treatment cataphoresis Casing painting polyester RAL 7042 Control unit 826 MPS incorporated Limit switc...

Page 5: ...ndation plinth as shown in Fig 8 and install the base plate providing one or more conduits for electrical cables Use a level to check that the plate is perfectly horizontal and wait for the cement to...

Page 6: ...ate Drill a 6 5 mm diameter hole and thread using 8 mm screw taps Tighten the bolt 4 Slide the gate manually making sure that the rack rests on the pinion and repeat the operations of point 3 5 Place...

Page 7: ...6 5 4 3 1 4 5 2 MODEL 820 EMC RF 860 MC RF figs 20 21 Insert the elastic pin 7 in the shaft with the aid of a hammer Fit the chain pinion on the shaft by matching up the pinion seats with the elastic...

Page 8: ...the 230 Vac terminals to which the flashing light must be connected 5 2 8 230 V MAINS SUPPLY terminals 13 14 These are the terminals to which the 230 Vac electricity supply must be connected Connect t...

Page 9: ...recloses 2 STOP no effect stops counting stops stops no effect SAFETY no effect recloses after 5 s stops and inverts motion when disengaged 2 no effect no effect TABLE 8 LOGIC A2 AUTOMATIC LOGIC S1 I...

Page 10: ...be positioned to ON for closure to left and OFF for closure to right The positions of dipswitches SW4 SW5 and SW6 have no effect 3 Move the gate manually to its mid travel position 4 Switch on the ele...

Page 11: ...by losing the centre scale position of the ADL the following steps must be carried out to restore the start condition 1 Release the operator 2 Slide the gate manually to the mid travel position 3 Remo...

Page 12: ...11 Fig 29 Fig 30 1 2 A B Fig 32 Fig 31 OIL...

Page 13: ...n has been selected a second impulse must be sent to reclose the gate An opening impulse send while the gate is reclosing causes it to change direction of movement A stop command if available stops mo...

Page 14: ...for either technical or commercial reasons at any time and without revising the present publication FAAC UK Limited 6 Hamilton Close Houndmills Estate Basingstoke RG21 6YT Telephone 01256 318100 Fax 0...