BOLTSCOPE PRO
- Bolt Tension Monitor
153
Setting the Alarm HI Limit
1) Assuming the
ALARM STATUS
is
ON
, use the
UP
and
DOWN
arrow
keys to scroll through the sub menu items until
ALARM HI LIMIT
is
highlighted.
2) Press the
LEFT
and
RIGHT
arrow keys to scroll the value. When the
correct alarm value is being displayed,
proceed to step 8
.
3)
Alternatively
, press the
ENTER
key to display the
Digits Edit Box
.
4) Press the
UP
and
DOWN
arrow keys to scroll the highlighted value.
5) Press the
LEFT
and
RIGHT
arrow keys to scroll the digit locations.
6) Repeat steps
4 & 5
until the
ALARM HI
value is correctly displayed.
7)
Press the
OK
key to set the
ALARM HI
value and return to the menu
screen, or
ESC
to cancel entering the
ALARM HI
value.
8)
Press the
MEAS
key to return to the measurement screen.
13.3 Polarity
Refer to section 12.7 interpreting the Waveform, for a detailed explanation on
how to select the proper polarity. The following procedures are the necessary
steps to change the polarity only.