BOLTSCOPE PRO
- Bolt Tension Monitor
27
Delete All Groups:
This function provides the user with the ability to delete all
groups currently stored in memory. Refer to section 14.5 for further info.
4.10 UTIL (utilities) – Menu
Temp Mode:
This sub menu item enables the user to select the automatic
temperature compensation mode (manual, semi-auto, and auto). This feature is
only available to those units purchased with the automatic temperature
compensation option and probe. Note: Contact hydratight for information on
upgrading the
BOLTSCOPE PRO
. Refer to Chapter 9 for further info.
Alarm Status:
Toggles alarm mode on or off. Refer to section 13.2 for further
info.
Alarm LO Limit:
Gives the user the ability to set the LO tolerance parameter. If
the measurement falls below this value, a red light will illuminate. Refer to section
13.2 for further info.
Alarm HI Limit:
Gives the user the ability to set the HI tolerance parameter. If
the measurement exceeds this value, a red light will illuminate. Refer to section
13.2 for further info.
4.11 XFER (transfer) – Menu
Backup Setups:
Enables the user the ability to backup the setups currently
stored in the
BOLTSCOPE PRO
to a PC via RS232 port. Refer to the help
section of the
BOLTSCOPE PROview
software for a complete electronic
manual.
Restore Setups:
Enables the user the ability to restore the setups currently
saved on a PC to a
BOLTSCOPE PRO
via RS232 port. Refer to the help