hydratight
152
3)
Use the
LEFT
and
RIGHT
arrow keys to toggle the
ALARM STATUS
on/off.
4)
Continue on to the next section
“Setting the Alarm Lo Limit”
.
Setting the Alarm LO Limit
1) Assuming the
ALARM STATUS
is
ON
, use the
UP
and
DOWN
arrow
keys to scroll through the sub menu items until
ALARM LO LIMIT
is
highlighted.
2) Press the
LEFT
and
RIGHT
arrow keys to scroll the value. When the
correct alarm value is being displayed,
proceed to step 7
.
3)
Alternatively
, press the
ENTER
key to display the
Digits Edit Box
.
4) Press the
UP
and
DOWN
arrow keys to scroll the highlighted value.
5) Press the
LEFT
and
RIGHT
arrow keys to scroll the digit locations.
6)
Repeat steps
4 & 5
until the
ALARM LO
value is correctly displayed.
7)
If only one limit will be used, press the
MEAS
key to return to the
measurement screen and begin taking readings. Otherwise, continue
on to set the
ALARM HI LIMIT
.