BOLTSCOPE PRO
- Bolt Tension Monitor
75
most significant – 6” bar. If the glass block is being used, it will have only
one velocity specified for the block.
19) Press the
ENTER
key to display the
Digits Edit Box
.
20) Press the
UP
and
DOWN
arrow keys to scroll the highlighted value.
21) Press the
LEFT
and
RIGHT
arrow keys to scroll the digit locations.
22) Repeat steps
20 & 21
until the
VELOCITY
value is correctly displayed.
23) Press the
OK
key to return to the
Two Point Zero
list, or
ESC
to cancel
entering the
VELOCITY
.
24) Press the
UP
and
DOWN
arrow keys to scroll through the
Two Point
Zero
list until
TEMP COEF
is highlighted.
Note:
This should be set to 55 (99 metric) for the 3 & 6” bars supplied by
hydratight. If the glass block is used, it should be set to 0. The reason for
this is because glass has a very low temperature coefficient.
25) Press the
ENTER
key to display the
Digits Edit Box
.
26) Press the
UP
and
DOWN
arrow keys to scroll the highlighted value.
27) Press the
LEFT
and
RIGHT
arrow keys to scroll the digit locations.
28) Repeat steps
26 & 27
until the
TEMP COEF
value is correctly
displayed.
29) Press the
OK
key to return to the
Two Point Zero
list, or
ESC
to cancel
entering the
TEMP COEF
.
30) Press the
ESC
key once to leave the
Two Point Zero
list.
31) Press the
MENU
key multiple times to tab right and the
ESC
key
multiple times to tab left until the
MATL
menu is highlighted and
displaying the submenu items.