64
Issue 3.3.2 / April, 2011
Program 05-02-IP : System Timing Parameters – 02
05-02-IP SYS PAR
5 5 1 2 1 0
2 4
IP = 01-08
System Default.
Item
Display
Timing
Pointer
Data
Programming Data Description
Table
Default
---------- ----------- ---------------------------------------------
---------- -------------
01
0-9
SLT Dial Tone Timeout
C
5=15 Sec.
02
0-9
SLT Inter-Digit Timeout
C
5=15 Sec.
03
0-9
Auto Redial Ringing Time
1=10 Sec.
04
0-9
SLT Release Signal
2=200 ms.
05
0-9
Flash Time - Key Phone
B
1=80 ms
.
06
0-9
SLT Hold Signal
I
0=100
ms.
07
0-9
Ring On Time
G
2=240 ms.
08
0-9
Ring Off Time
F
4=4 Sec.
Description:
01. SLT Dial Tone Timeout:
This parameter is for Single Line Telephones. If a key is not pressed before the assigned time period
expires when Dial Tone is given, a Busy Tone will be heard.
02. SLT Inter-Digit Timeout:
This parameter is for Single Line Telephones. If the interval between digits dialled exceeds the assigned
time period, a Busy Tone will be given.
See timing table Grade C for parameters of these features.
03. Auto Redial Ringing Time – PSTN lines:
This parameter is the time duration for which the system will redial the telephone number automatically
and then hang up during Auto Redial on PSTN lines. ISDN lines will hang up immediately if the called
number is busy.
1 = 10 sec. 2 = 20 sec. ...... 9 = 90 sec.
Off Hook
Auto-Redial Pause Time
(Program 05-05-08), Y
seconds
Off Hook
Auto-Redial Ringing
Timer
On
Hook
Auto-Redial Ringing
Timer
04. SLT Release Signal:
This parameter is the time duration of depressing the hook switch of an SLT that the system will see as a
hang up, the system will take it as a hold signal if less than this time but longer than the SLT hook flash
time.
0 = 100 ms
1 = 200 ms
2 = 300 ms
3 = 400 ms
4 = 600 ms
5 = 800 ms
6 = 1000 ms
7 =1200 ms
8 = 1400 ms
9 = 1600 ms
Summary of Contents for G1E
Page 16: ...Issue 3 3 2 April 2011 ...
Page 26: ......
Page 30: ...14 Issue 3 3 2 April 2011 G1E Main Equipment with MSC VMC 2 TKU s 2 STU s Installed ...
Page 31: ...G1E Programming Manual 15 G1E Main Equipment ...
Page 69: ...G1E Programming Manual 53 PROGRAMMING INFORMATION ...
Page 74: ...58 Issue 3 3 2 April 2011 ...
Page 75: ...G1E Programming Manual 59 PROGRAM MODES ...
Page 117: ...G1E Programming Manual 101 07 Reserved 08 Reserved ...
Page 119: ...G1E Programming Manual 103 07 Reserved 08 Reserved ...
Page 121: ...G1E Programming Manual 105 07 Reserved 08 Reserved ...
Page 127: ...G1E Programming Manual 111 ...
Page 169: ...G1E Programming Manual 153 ...
Page 171: ...G1E Programming Manual 155 05 Reserved 06 Reserved 07 Reserved 08 Reserved ...
Page 218: ......