G1E - General Description
1
General Description - Introduction
The General Description section contains an easy to understand overview of the
HYBREX
®
G1E and G1E+
ISDN/VOIP Digital Telephone System. It is the intent of this document to provide technical readers with
information pertaining to the system building blocks, capabilities, key highlights, electrical, physical and
environmental characteristics of the
HYBREX
G1E/G1E+ ISDN/VOIP Digital Telephone System.
Single Cabinet system
The G1E/G1E+ systems are provided as a 4 line, 8 digital 4 analogue extension system using a traditional
Hybrex programming interface. It is upgradeable within a single cabinet to a total of 28 extensions, either 24
digital and 4 analogue or 8 digital and 20 analogue extensions. There are 2 trunk positions available and these
can be either PSTN, Basic rate ISDN or VOIP in any combination. The maximum number of trunks per cabinet
utilising PSTN is 8 or ISDN 12. Currently VOIP is 6 trunks until the release of the ITU card in 2009.
Multi Cabinet System.
The G1E+ system has the ability to be fitted with an MPU4 card to the MBU. The MPU4 card will allow the
cabinet to be a master to between 1 and 4 cabinets and the operating system to be converted to the GDS
software with all GDS feature sets available.
Expansion Cabinets
Expansion cabinets for the G1E+ system are a standard G1E+ main equipment with the MXU4 card fitted
allowing the cabinet to connect to the MPU4 of the master cabinet. Each additional cabinet adds the full extra
capacity of the cabinet.
Single cabinet with MPU4
A single cabinet system with an MPU4 will have all the programming and features of a GDS system. This will
allow small customers to still have advanced features and operating convenience without the cost of a GDS
system.
Card Compatibility G1E and G1E+
The following cards are compatible between the G1E and the G1E+ without any modification.
G1E-STU, G1E-SLU. G1E-TKU, G1E-SIU, G1E-VSC.
The G1E-MSU is only for the G1E system. All features of G1E MSU are installed as standard on the G1E+ MBU.
The G1E-VIU is only compatible with a G1E+ by either installing only the small ribbon cable from CN1 to the
MBU or if installing the large ribbon cable it will need to be modified as per the install manual.
The G1E-ITU, G1E-ISU and G1E-VSC2 are only able to be installed in the G1E+. These card are scheduled to
be available by mid 2009.
The Main cabinet, Power supply, RGU and battery backup are common to both systems.
Summary of Contents for G1E
Page 16: ...Issue 3 3 2 April 2011 ...
Page 26: ......
Page 30: ...14 Issue 3 3 2 April 2011 G1E Main Equipment with MSC VMC 2 TKU s 2 STU s Installed ...
Page 31: ...G1E Programming Manual 15 G1E Main Equipment ...
Page 69: ...G1E Programming Manual 53 PROGRAMMING INFORMATION ...
Page 74: ...58 Issue 3 3 2 April 2011 ...
Page 75: ...G1E Programming Manual 59 PROGRAM MODES ...
Page 117: ...G1E Programming Manual 101 07 Reserved 08 Reserved ...
Page 119: ...G1E Programming Manual 103 07 Reserved 08 Reserved ...
Page 121: ...G1E Programming Manual 105 07 Reserved 08 Reserved ...
Page 127: ...G1E Programming Manual 111 ...
Page 169: ...G1E Programming Manual 153 ...
Page 171: ...G1E Programming Manual 155 05 Reserved 06 Reserved 07 Reserved 08 Reserved ...
Page 218: ......