152
Software Version Check
Description
Dealers will be required from time to time when calling Hybrex technical support for assistance to provide
us with certain information regarding the Version levels of software in the system.
Conditions
When calling technical support you must be at a digital display telephone equipped with an LCD.
Programming
Automatic Operation: While the telephone set is idle press [6 6].
The following will be displayed:
Superkey G1824 U
V: G1-A01GE P: 31
The system type is displayed in the upper portion of the LCD.
The upper right identifies the status of the customer database.
U: means the system or personnel data is programmed with information set by users.
u: means the system is storing the data back to Flash memory in the background mode.
T: means the checksum of flash memory is not correct. It could be the situation that users has
added one more card into the system. Enter system programming and SAVE the
data back to the flash memory again can correct this fault.
S: signifies the system is in a default status
.
The lower portion of the display identifies the current system software version. The right hand portion of
the display identifies the port number from where you are viewing the information.
Press [Vol Up]. The display changes to:
SMDR unlocked
V: G1-A01GE P: 31
This gives you the current status of the SMDR port.
Press [Vol Up] again
Line S.: 00000
V: G1-A01GE P: 31
This is engineering code for Hybrex purposes only.
Press [Vol Up] again.
Frm:0000Tim:001E
BkE:0009BkS:0082
Frm:
"Frame" error of the digital signal between the KSU and the digital phone. If this counter is running
at a very fast rate, it indicates something wrong either on the cable, KSU hardware or digital telephone
hardware.
Tim:
"Timeout" of the digital signal transmission between the KSU and the digital phone. The system load
will also affect this value. It is for our engineers to evaluate the system load.
BkE:
The error "status" (not the counter) when system stores the data into the flash memory. It's for our
engineers to observe the proceeding result of the flash memory. Users don't need to worry about this
value because the system will repeat the entire procedure until the data is really stored into the flash
memory.
BkS:
The backup times of flash memory. It's for our engineer to evaluate and make some statistic on the
"life" of the flash memory according to user operation