83
Environment Monitor
Description
Environment Monitor allows a G1-824i digital telephone to monitor the ambient room audio of another G1-
824i digital telephone equipped with a speaker phone.
Conditions
In order to invoke an Environment Monitor, the station requesting the monitor must have a higher monitor
classification than the station to be monitored.
It is suggested that this function be invoked on stations that are equipped with speaker phone capability.
It is not recommended that Environment Monitor be used on single line telephones.
A telephone set to be used as an Environment Monitor must be idle.
Programming
A station that is to perform monitoring must have Mode 40-STN-02 set at a level (1-9) that is higher than
the station it is to monitor.
Any station to be monitored must have Mode 40-STN-02 set a level (0-8) that is lower than the station
that will invoke the monitor.
Operation
1. Dial [7],[7],[4] Dial the station number to be monitored.
2. If the station is idle, you will be connected to the station. The monitored station's Microphone will
be activated.
3. If the station goes off hook for any reason, the monitor will be terminated
Note:
Environmental monitor is a one way audio path