The server supports rear cabling and network controller sideband interface
(NC-SI).
●
The HMM provides an aggregation network port on the front panel through
the port aggregation module. This aggregation network port is connected to
the iBMC of the four server nodes using one management network cable. This
means that only one port for the out-of-band management system interfaces
with external devices.
shows the server system architecture.
Figure 3-1 Server system architecture
3.2 Cooling Design
The X6000 has the following features in cooling design:
●
The server draws cool air in from the front panel of the chassis, delivers the
cool air through the disks, fan modules, backplane to the four server nodes,
and then to the processors and dual in-line memory modules (DIMMs), and
then exhausts air from the rear.
●
The X6000 uses four 8080 counter rotary fans with high wind pressure to
provide industry-leading cooling and power-saving capabilities.
●
The 8080 fans use DTS 2.0 control to ensure low power consumption.
●
The X6000 minimizes noise through speed adjustment, shock absorption, and
noise isolation design.
●
The high-pressure counter-rotating fans provide a 10% more air volume than
normal fans. The refined air channels implement concentrated cooling of