Procedure
Step 1 Wear an ESD wrist strap or ESD gloves.
Step 2 Hold down the tabs on the multi-port connector on a multi-port cable, as shown
in (1) in
.
Figure 4-21 Connecting a multi-port cable
Step 3 Align the connector with the UCP on the server node panel, and gently push the
connector into the UCP until it cannot move forward, as shown in (2) in
.
----End
4.5.4 Connecting an Optical Cable
Precautions
●
Install an optical module in an optical port before connecting the optical
cable.
●
To avoid damage to an optical module, do not exert excessive force to remove
or insert it.
●
To avoid damage to an optical module, do not frequently or quickly remove
or insert it.
Procedure
Step 1 Wear an ESD wrist strap or ESD gloves.
Step 2 Remove the dust-proof cap from an optical module. See (1) in
.
TaiShan X6000 Server
User Guide
4 Installing the X6000